Change history for item: COSMOGAS MYDENS 24P 25 kW double circuit

  1. Donny Darko 09 July 2023 15:58:12
    1. Create: Description #3620774
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3620775
      Value: Gas, condensing
    3. Create: Burner #3620776
      Value: Gas
    4. Create: Number of circuits #3620777
      Value: Double-circuit
    5. Create: Thermal power #3620778
      Value: 3.17 - 25 kW
    6. Create: Thermal load #3620779
      Value: 3.20 - 25.50 kW
    7. Create: The combustion chamber #3620780
      Value: Closed
    8. Create: Efficiency #3620781
      Value: 108 %
    9. Create: Control #3620782
      Value: Electronic
    10. Create: Installation #3620783
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3620784
      Value: Stainless steel
    12. Create: Mains voltage #3620785
      Value: Single-phase
    13. Create: Peculiarities #3620786
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3620787
      Value: 10 l
    15. Create: Equipment #3620788
      Value: Display
    16. Create: Fuel #3620789
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3620790
      Value: 2.7 cu. m/hour
    18. Create: LPG consumption #3620791
      Value: 1.98 kg/hour
    19. Create: Nominal pressure of natural gas #3620792
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3620793
      Value: 37 mbar
    21. Create: Heat carrier temperature #3620794
      Value: 20 - 80 °C
    22. Create: Temperature in the DHW circuit #3620795
      Value: 40 - 60 °С
    23. Create: Hot water capacity at t 30°C #3620796
      Value: 13.1 l/min
    24. Create: Max. water pressure in the DHW circuit #3620797
      Value: 7 bar
    25. Create: Max. water pressure in the heating circuit #3620798
      Value: 3 bar
    26. Create: Gas connection #3620799
      Value: 3/4"
    27. Create: Heating circuit connection #3620800
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3620801
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3620802
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3620803
      Value: 445x770x305 mm
    31. Create: Weight #3620804
      Value: 36 kg
    32. Create: Image #6361236
      URL: https://avatars.mds.yandex.net/get-mpic/372220/img_id9124628713943675157.jpeg/orig
    33. Create: Preview image #6361237
      URL: https://avatars.mds.yandex.net/get-mpic/372220/img_id9124628713943675157.jpeg/orig
  2. Donny Darko 30 April 2023 09:20:17
    Name: COSMOGAS MYDENS 24P 25 kW double circuit; Catalog: Heating boilers