Change history for item: RADIANT RCA 28 /25 26.67 kW double circuit

  1. Donny Darko 09 July 2023 15:57:53
    1. Create: Description #3620692
      Value: Type of heating boiler: gas, max. thermal power: 26.67 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3620693
      Value: Gas, convection
    3. Create: Burner #3620694
      Value: Gas
    4. Create: Number of circuits #3620695
      Value: Double-circuit
    5. Create: Thermal power #3620696
      Value: 15.20 - 26.67 kW
    6. Create: Thermal load #3620697
      Value: 17.50 - 29.80 kW
    7. Create: The combustion chamber #3620698
      Value: Open
    8. Create: Efficiency #3620699
      Value: 89.5 %
    9. Create: Control #3620700
      Value: Electronic
    10. Create: Installation #3620701
      Value: Wall-mounted
    11. Create: Mains voltage #3620702
      Value: Single-phase
    12. Create: Peculiarities #3620703
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3620704
      Value: 25 l
    14. Create: Expansion tank volume #3620705
      Value: 10 l
    15. Create: Equipment #3620706
      Value: Built-in boiler, display
    16. Create: Fuel #3620707
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3620708
      Value: 3.12 cu. m/hour
    18. Create: LPG consumption #3620709
      Value: 2.35 kg/hour
    19. Create: Nominal pressure of natural gas #3620710
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3620711
      Value: 37 mbar
    21. Create: Heat carrier temperature #3620712
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3620713
      Value: 35 - 60 °С
    23. Create: Hot water capacity at t 40°C #3620714
      Value: 13.25 l/min
    24. Create: Max. water pressure in the DHW circuit #3620715
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3620716
      Value: 3 bar
    26. Create: Gas connection #3620717
      Value: 3/4"
    27. Create: Heating circuit connection #3620718
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3620719
      Value: 1/2"
    29. Create: Chimney diameter #3620720
      Value: 130 mm
    30. Create: Dimensions WxHxD #3620721
      Value: 490x900x450 mm
    31. Create: Weight #3620722
      Value: 70 kg
    32. Create: Image #6361230
      URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id6147003045445357365.jpeg/orig
    33. Create: Preview image #6361231
      URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id6147003045445357365.jpeg/orig
  2. Donny Darko 30 April 2023 09:20:16
    Name: RADIANT RCA 28 /25 26.67 kW double circuit; Catalog: Heating boilers