Donny Darko 09 July 2023 15:57:07
Create:
Description #3620578
Value: Type of heating boiler: gas, max. heating power: 27.86 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3620579
Value: Gas, convection
Create:
Burner #3620580
Value: Gas
Create:
Number of circuits #3620581
Value: Double-circuit
Create:
Thermal power #3620582
Value: 15.82 - 27.86 kW
Create:
Thermal load #3620583
Value: 17.50 - 29.80 kW
Create:
The combustion chamber #3620584
Value: Closed
Create:
Efficiency #3620585
Value: 93.5 %
Create:
Control #3620586
Value: Electronic
Create:
Installation #3620587
Value: Wall-mounted
Create:
Mains voltage #3620588
Value: Single-phase
Create:
Peculiarities #3620589
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3620590
Value: 25 l
Create:
Expansion tank volume #3620591
Value: 10 l
Create:
Equipment #3620592
Value: Built-in boiler, display
Create:
Fuel #3620593
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3620594
Value: 3.16 cu. m/hour
Create:
LPG consumption #3620595
Value: 2.35 kg/hour
Create:
Nominal pressure of natural gas #3620596
Value: 20 mbar
Create:
Permissible LPG pressure #3620597
Value: 37 mbar
Create:
Heat carrier temperature #3620598
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3620599
Value: 35 - 60 °С
Create:
Hot water capacity at t 40°C #3620600
Value: 13.6 l/min
Create:
Max. water pressure in the DHW circuit #3620601
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3620602
Value: 3 bar
Create:
Gas connection #3620603
Value: 3/4"
Create:
Heating circuit connection #3620604
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3620605
Value: 1/2"
Create:
Coaxial chimney diameter #3620606
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3620607
Value: Yes
Create:
Dimensions WxHxD #3620608
Value: 490x900x450 mm
Create:
Weight #3620609
Value: 72 kg
Create:
Image #6361222
URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id8743529018826177563.jpeg/orig
Create:
Preview image #6361223
URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id8743529018826177563.jpeg/orig
Donny Darko 30 April 2023 09:20:15
Name: RADIANT RSA 28 /25 27.86 kW double circuit; Catalog: Heating boilers