Change history for item: RADIANT RSR 28

  1. Donny Darko 09 July 2023 15:56:20
    1. Create: Description #3620455
      Value: Type of heating boiler: gas, max. heating power: 27.86 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3620456
      Value: Gas, convection
    3. Create: Burner #3620457
      Value: Gas
    4. Create: Number of circuits #3620458
      Value: Double-circuit
    5. Create: Thermal power #3620459
      Value: 15.82 - 27.86 kW
    6. Create: Thermal load #3620460
      Value: 17.50 - 29.80 kW
    7. Create: The combustion chamber #3620461
      Value: Closed
    8. Create: Efficiency #3620462
      Value: 93.5 %
    9. Create: Control #3620463
      Value: Electronic
    10. Create: Installation #3620464
      Value: Wall-mounted
    11. Create: Mains voltage #3620465
      Value: Single-phase
    12. Create: Peculiarities #3620466
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3620467
      Value: 8 l
    14. Create: Equipment #3620468
      Value: Display
    15. Create: Fuel #3620469
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3620470
      Value: 3.16 cu. m/hour
    17. Create: LPG consumption #3620471
      Value: 2.35 kg/hour
    18. Create: Nominal pressure of natural gas #3620472
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3620473
      Value: 37 mbar
    20. Create: Heat carrier temperature #3620474
      Value: 30 - 80 °С
    21. Create: Temperature in the DHW circuit #3620475
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 30°C #3620476
      Value: 13.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3620477
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3620478
      Value: 3 bar
    25. Create: Gas connection #3620479
      Value: 3/4"
    26. Create: Heating circuit connection #3620480
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3620481
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3620482
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3620483
      Value: Yes
    30. Create: Dimensions WxHxD #3620484
      Value: 450x780x330 mm
    31. Create: Weight #3620485
      Value: 42 kg
    32. Create: Image #6361214
      URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id1069798669153109650.jpeg/orig
    33. Create: Preview image #6361215
      URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id1069798669153109650.jpeg/orig
  2. Donny Darko 30 April 2023 09:20:14
    Name: RADIANT RSR 28; Catalog: Heating boilers