Change history for item: Federica Bugatti 24 ATMO bypass

  1. Donny Darko 09 July 2023 15:33:26
    1. Create: Description #3616663
      Value: Type of heating boiler: gas, max. heating power: 24.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, control: mechanical
    2. Create: Type of heating boiler #3616664
      Value: Gas, convection
    3. Create: Burner #3616665
      Value: Gas
    4. Create: Number of circuits #3616666
      Value: Double-circuit
    5. Create: Thermal power #3616667
      Value: 9.50 - 24.10 kW
    6. Create: Thermal load #3616668
      Value: 11 - 26.60 kW
    7. Create: The combustion chamber #3616669
      Value: Open
    8. Create: Efficiency #3616670
      Value: 90.8 %
    9. Create: Control #3616671
      Value: Mechanical
    10. Create: Installation #3616672
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3616673
      Value: Stainless steel
    12. Create: Peculiarities #3616674
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3616675
      Value: 8 l
    14. Create: Fuel #3616676
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3616677
      Value: 2.82 cu. m/hour
    16. Create: LPG consumption #3616678
      Value: 2.1 kg/hour
    17. Create: Nominal pressure of natural gas #3616679
      Value: 17 - 35 mbar
    18. Create: Permissible LPG pressure #3616680
      Value: 45 mbar
    19. Create: Heat carrier temperature #3616681
      Value: 38 - 85 °С
    20. Create: Temperature in the DHW circuit #3616682
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3616683
      Value: 13.8 l/min
    22. Create: Hot water capacity at t 35°C #3616684
      Value: 9.9 l/min
    23. Create: Max. water pressure in the DHW circuit #3616685
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3616686
      Value: 3 bar
    25. Create: Gas connection #3616687
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3616688
      Value: 1/2"
    27. Create: Dimensions WxHxD #3616689
      Value: 400x703x325 mm
    28. Create: Weight #3616690
      Value: 30.7 kg
    29. Create: Image #6360411
      URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id8482477793147642400.jpeg/orig
    30. Create: Image #6360412
      URL: https://avatars.mds.yandex.net/get-mpic/3590777/img_id6954718706198803568.jpeg/orig
    31. Create: Image #6360413
      URL: https://avatars.mds.yandex.net/get-mpic/4615588/img_id2128580779816419510.jpeg/orig
    32. Create: Image #6360414
      URL: https://avatars.mds.yandex.net/get-mpic/5219133/img_id5757432120063427973.jpeg/orig
    33. Create: Preview image #6360415
      URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id8482477793147642400.jpeg/orig
  2. Donny Darko 30 April 2023 09:19:15
    Name: Federica Bugatti 24 ATMO bypass; Catalog: Heating boilers