Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 15:33:20
Create:
Description #3616633
Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3616634
Value: Gas, convection
Create:
Burner #3616635
Value: Gas
Create:
Number of circuits #3616636
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3616637
Value: 9.90 - 23.80 kW
Create:
Thermal load #3616638
Value: 11.30 - 25.70 kW
Create:
The combustion chamber #3616639
Value: Closed
Create:
Efficiency #3616640
Value: 92.8 %
Create:
Control #3616641
Value: Electronic
Create:
Installation #3616642
Value: Wall-mounted
Create:
Mains voltage #3616643
Value: Single-phase
Create:
Peculiarities #3616644
Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3616645
Value: 8 l
Create:
Equipment #3616646
Value: Display
Create:
Fuel #3616647
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3616648
Value: 2.72 cu. m/hour
Create:
LPG consumption #3616649
Value: 2.03 kg/h
Create:
Nominal pressure of natural gas #3616650
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3616651
Value: 45 mbar
Create:
Heat carrier temperature #3616652
Value: 38 - 85 °С
Create:
Temperature in the DHW circuit #3616653
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3616654
Value: 13.5 l/min
Create:
Hot water capacity at t 35°C #3616655
Value: 9.7 l/min
Create:
Max. water pressure in the DHW circuit #3616656
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3616657
Value: 3 bar
Create:
Gas connection #3616658
Value: 3/4"
Create:
Coaxial chimney diameter #3616659
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3616660
Value: Yes
Create:
Dimensions WxHxD #3616661
Value: 327x702x400mm
Create:
Weight #3616662
Value: 30 kg
Create:
Image #6360408
URL: https://avatars.mds.yandex.net/get-mpic/1865278/img_id4859128987075917897.jpeg/orig
Create:
Image #6360409
URL: https://avatars.mds.yandex.net/get-mpic/4880383/img_id2869424767541015169.jpeg/orig
Create:
Preview image #6360410
URL: https://avatars.mds.yandex.net/get-mpic/1865278/img_id4859128987075917897.jpeg/orig
Donny Darko 30 April 2023 09:19:15
Name: Federica Bugatti 24 Bithermal 23.8 kW bypass; Catalog: Heating boilers