Change history for item: Federica Bugatti 24 Bithermal 23.8 kW bypass

  1. Donny Darko 09 July 2023 15:33:20
    1. Create: Description #3616633
      Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3616634
      Value: Gas, convection
    3. Create: Burner #3616635
      Value: Gas
    4. Create: Number of circuits #3616636
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3616637
      Value: 9.90 - 23.80 kW
    6. Create: Thermal load #3616638
      Value: 11.30 - 25.70 kW
    7. Create: The combustion chamber #3616639
      Value: Closed
    8. Create: Efficiency #3616640
      Value: 92.8 %
    9. Create: Control #3616641
      Value: Electronic
    10. Create: Installation #3616642
      Value: Wall-mounted
    11. Create: Mains voltage #3616643
      Value: Single-phase
    12. Create: Peculiarities #3616644
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3616645
      Value: 8 l
    14. Create: Equipment #3616646
      Value: Display
    15. Create: Fuel #3616647
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3616648
      Value: 2.72 cu. m/hour
    17. Create: LPG consumption #3616649
      Value: 2.03 kg/h
    18. Create: Nominal pressure of natural gas #3616650
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3616651
      Value: 45 mbar
    20. Create: Heat carrier temperature #3616652
      Value: 38 - 85 °С
    21. Create: Temperature in the DHW circuit #3616653
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3616654
      Value: 13.5 l/min
    23. Create: Hot water capacity at t 35°C #3616655
      Value: 9.7 l/min
    24. Create: Max. water pressure in the DHW circuit #3616656
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3616657
      Value: 3 bar
    26. Create: Gas connection #3616658
      Value: 3/4"
    27. Create: Coaxial chimney diameter #3616659
      Value: 60/100 mm and 80/125 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3616660
      Value: Yes
    29. Create: Dimensions WxHxD #3616661
      Value: 327x702x400mm
    30. Create: Weight #3616662
      Value: 30 kg
    31. Create: Image #6360408
      URL: https://avatars.mds.yandex.net/get-mpic/1865278/img_id4859128987075917897.jpeg/orig
    32. Create: Image #6360409
      URL: https://avatars.mds.yandex.net/get-mpic/4880383/img_id2869424767541015169.jpeg/orig
    33. Create: Preview image #6360410
      URL: https://avatars.mds.yandex.net/get-mpic/1865278/img_id4859128987075917897.jpeg/orig
  2. Donny Darko 30 April 2023 09:19:15
    Name: Federica Bugatti 24 Bithermal 23.8 kW bypass; Catalog: Heating boilers