Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 15:32:55
Create:
Description #3616506
Value: Type of heating boiler: gas, max. heating power: 30.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3616507
Value: Gas, convection
Create:
Burner #3616508
Value: Gas
Create:
Number of circuits #3616509
Value: Double-circuit
Create:
Thermal power #3616510
Value: 18 - 30.60 kW
Create:
Thermal load #3616511
Value: 20 - 33.90 kW
Create:
The combustion chamber #3616512
Value: Closed
Create:
Efficiency #3616513
Value: 93.1 %
Create:
Control #3616514
Value: Electronic
Create:
Installation #3616515
Value: Wall-mounted
Create:
Primary heat exchanger material #3616516
Value: Copper
Create:
Secondary heat exchanger material #3616517
Value: Stainless steel
Create:
Mains voltage #3616518
Value: Single-phase
Create:
Peculiarities #3616519
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3616520
Value: 8 l
Create:
Fuel #3616521
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3616522
Value: 3.59 cu. m/hour
Create:
LPG consumption #3616523
Value: 2.67 kg/h
Create:
Nominal pressure of natural gas #3616524
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3616525
Value: 45 mbar
Create:
Heat carrier temperature #3616526
Value: 38 - 85 °С
Create:
Temperature in the DHW circuit #3616527
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3616528
Value: 17.5 l/min
Create:
Hot water capacity at t 35°C #3616529
Value: 12.5 l/min
Create:
Max. water pressure in the DHW circuit #3616530
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3616531
Value: 3 bar
Create:
Gas connection #3616532
Value: 3/4"
Create:
Heating circuit connection #3616533
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3616534
Value: 1/2"
Create:
Coaxial chimney diameter #3616535
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3616536
Value: Yes
Create:
Dimensions WxHxD #3616537
Value: 400x703x325 mm
Create:
Weight #3616538
Value: 32.5 kg
Create:
Image #6360364
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id8672915731808942773/orig
Create:
Image #6360365
URL: https://avatars.mds.yandex.net/get-mpic/5167413/img_id7573693077540737851.jpeg/orig
Create:
Preview image #6360366
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id8672915731808942773/orig
Donny Darko 30 April 2023 09:19:14
Name: Federica Bugatti 32 Turbo 30.6 kW bypass; Catalog: Heating boilers