Donny Darko 09 July 2023 15:32:49
Create:
Description #3616473
Value: Type of heating boiler: gas, max. heating power: 29.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3616474
Value: Gas, convection
Create:
Burner #3616475
Value: Gas
Create:
Number of circuits #3616476
Value: Double-circuit
Create:
Thermal power #3616477
Value: 14.90 - 29.10 kW
Create:
Thermal load #3616478
Value: 16.50 - 31.10 kW
Create:
The combustion chamber #3616479
Value: Closed
Create:
Efficiency #3616480
Value: 93.3 %
Create:
Control #3616481
Value: Electronic
Create:
Installation #3616482
Value: Wall-mounted
Create:
Primary heat exchanger material #3616483
Value: Copper
Create:
Secondary heat exchanger material #3616484
Value: Stainless steel
Create:
Mains voltage #3616485
Value: Single-phase
Create:
Peculiarities #3616486
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3616487
Value: 8 l
Create:
Fuel #3616488
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3616489
Value: 3.29 cu. m/hour
Create:
LPG consumption #3616490
Value: 2.45 kg/hour
Create:
Nominal pressure of natural gas #3616491
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3616492
Value: 45 mbar
Create:
Heat carrier temperature #3616493
Value: 38 - 85 °С
Create:
Temperature in the DHW circuit #3616494
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3616495
Value: 16.7 l/min
Create:
Hot water capacity at t 35°C #3616496
Value: 11.9 l/min
Create:
Max. water pressure in the DHW circuit #3616497
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3616498
Value: 3 bar
Create:
Gas connection #3616499
Value: 3/4"
Create:
Heating circuit connection #3616500
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3616501
Value: 1/2"
Create:
Coaxial chimney diameter #3616502
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3616503
Value: Yes
Create:
Dimensions WxHxD #3616504
Value: 400x703x325 mm
Create:
Weight #3616505
Value: 32.5 kg
Create:
Image #6360362
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id8672915731808942773/orig
Create:
Preview image #6360363
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id8672915731808942773/orig
Donny Darko 30 April 2023 09:19:14
Name: Federica Bugatti 28 Turbo 29.1 kW bypass; Catalog: Heating boilers