Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3616441
Value: Gas, convection
Create:
Burner #3616442
Value: Gas
Create:
Number of circuits #3616443
Value: Double-circuit
Create:
Thermal power #3616444
Value: 12.90 - 23.70 kW
Create:
Thermal load #3616445
Value: 14.50 - 25.50 kW
Create:
The combustion chamber #3616446
Value: Closed
Create:
Efficiency #3616447
Value: 92.8 %
Create:
Control #3616448
Value: Electronic
Create:
Installation #3616449
Value: Wall-mounted
Create:
Primary heat exchanger material #3616450
Value: Copper
Create:
Secondary heat exchanger material #3616451
Value: Stainless steel
Create:
Mains voltage #3616452
Value: Single-phase
Create:
Peculiarities #3616453
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3616454
Value: 8 l
Create:
Fuel #3616455
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3616456
Value: 2.7 cu. m/hour
Create:
LPG consumption #3616457
Value: 1.98 kg/hour
Create:
Nominal pressure of natural gas #3616458
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3616459
Value: 45 mbar
Create:
Heat carrier temperature #3616460
Value: 38 - 85 °С
Create:
Temperature in the DHW circuit #3616461
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3616462
Value: 13.6 l/min
Create:
Hot water capacity at t 35°C #3616463
Value: 9.7 l/min
Create:
Max. water pressure in the DHW circuit #3616464
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3616465
Value: 3 bar
Create:
Gas connection #3616466
Value: 3/4"
Create:
Heating circuit connection #3616467
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3616468
Value: 1/2"
Create:
Coaxial chimney diameter #3616469
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3616470
Value: Yes
Create:
Dimensions WxHxD #3616471
Value: 400x703x325 mm
Create:
Weight #3616472
Value: 32.5 kg
Create:
Image #6360359
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id8672915731808942773/orig
Create:
Image #6360360
URL: https://avatars.mds.yandex.net/get-mpic/5146791/img_id970098055484629719.jpeg/orig
Create:
Preview image #6360361
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id8672915731808942773/orig
Donny Darko 30 April 2023 09:19:13
Name: Federica Bugatti 24 Turbo 23.7 kW bypass; Catalog: Heating boilers