Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 18:05:49
Create:
Built-in circulation pump #3637959
Value: There is
Create:
Built-in expansion tank #3637960
Value: There is
Create:
Functions #3637961
Value: Frost protection, thermometer, manometer
Create:
Protection #3637962
Value: Gas control, safety valve, air vent
Donny Darko 09 July 2023 15:04:10
Create:
Description #3613022
Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3613023
Value: Gas, convection
Create:
Burner #3613024
Value: Gas
Create:
Number of circuits #3613025
Value: Double-circuit
Create:
Thermal power #3613026
Value: 10.50 - 28 kW
Create:
Thermal load #3613027
Value: 12.50 - 31 kW
Create:
The combustion chamber #3613028
Value: Closed
Create:
Efficiency #3613029
Value: 90.3 %
Create:
Control #3613030
Value: Electronic
Create:
Installation #3613031
Value: Wall-mounted
Create:
Primary heat exchanger material #3613032
Value: Copper
Create:
Secondary heat exchanger material #3613033
Value: Stainless steel
Create:
Mains voltage #3613034
Value: Single-phase
Create:
Peculiarities #3613035
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3613036
Value: 10 l
Create:
Equipment #3613037
Value: Display
Create:
Fuel #3613038
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3613039
Value: 3.2 cu. m/hour
Create:
LPG consumption #3613040
Value: 2.8 kg/hour
Create:
Nominal pressure of natural gas #3613041
Value: 13 - 28 mbar
Create:
Permissible LPG pressure #3613042
Value: 37 mbar
Create:
Heat carrier temperature #3613043
Value: 40 - 85 °С
Create:
Temperature in the DHW circuit #3613044
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3613045
Value: 16.1 l/min
Create:
Max. water pressure in the DHW circuit #3613046
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3613047
Value: 3 bar
Create:
Gas connection #3613048
Value: 3/4"
Create:
Heating circuit connection #3613049
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3613050
Value: 1/2"
Create:
Coaxial chimney diameter #3613051
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3613052
Value: Yes
Create:
Dimensions WxHxD #3613053
Value: 488x827x345mm
Create:
Weight #3613054
Value: 42 kg
Create:
Image #6359077
URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id4815981876252484250/orig
Create:
Preview image #6359078
URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id4815981876252484250/orig
Donny Darko 30 April 2023 09:18:14
Name: Gas boiler Zoom Boilers Expert 28 BF 28 kW double-circuit; Catalog: Heating boilers