Change history for item: Gas boiler Alpha CB 24 TF 23.8 kW double-circuit

  1. Donny Darko 09 July 2023 14:50:49
    1. Create: Description #3610598
      Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3610599
      Value: Gas, convection
    3. Create: Burner #3610600
      Value: Gas
    4. Create: Number of circuits #3610601
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3610602
      Value: 6.80 - 23.80 kW
    6. Create: The combustion chamber #3610603
      Value: Closed
    7. Create: Efficiency #3610604
      Value: 93.4 %
    8. Create: Control #3610605
      Value: Electronic
    9. Create: Installation #3610606
      Value: Wall-mounted
    10. Create: Mains voltage #3610607
      Value: Single-phase
    11. Create: Peculiarities #3610608
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3610609
      Value: 6 l
    13. Create: Equipment #3610610
      Value: Display
    14. Create: Fuel #3610611
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3610612
      Value: 2.7 cu. m/hour
    16. Create: Nominal pressure of natural gas #3610613
      Value: 20 - 29 mbar
    17. Create: Permissible LPG pressure #3610614
      Value: 37 mbar
    18. Create: Heat carrier temperature #3610615
      Value: 35 - 80 °С
    19. Create: Temperature in the DHW circuit #3610616
      Value: 35 - 55 °С
    20. Create: Hot water capacity at t 30°C #3610617
      Value: 11.1 l/min
    21. Create: Max. water pressure in the DHW circuit #3610618
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3610619
      Value: 3 bar
    23. Create: Gas connection #3610620
      Value: 3/4"
    24. Create: Heating circuit connection #3610621
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3610622
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3610623
      Value: 60/100 mm and 80/125 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3610624
      Value: Yes
    28. Create: Dimensions WxHxD #3610625
      Value: 440x756x240mm
    29. Create: Weight #3610626
      Value: 29 kg
    30. Create: Image #6358810
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id263997713185162810.jpeg/orig
    31. Create: Preview image #6358811
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id263997713185162810.jpeg/orig
  2. Donny Darko 30 April 2023 09:17:36
    Name: Gas boiler Alpha CB 24 TF 23.8 kW double-circuit; Catalog: Heating boilers