Change history for item: Gas boiler Alpha CB 24 TN 23.6 kW double-circuit

  1. Donny Darko 09 July 2023 14:50:28
    1. Create: Description #3610569
      Value: Type of heating boiler: gas, max. heating power: 23.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3610570
      Value: Gas, convection
    3. Create: Burner #3610571
      Value: Gas
    4. Create: Number of circuits #3610572
      Value: Double-circuit
    5. Create: Thermal power #3610573
      Value: 7 - 23.60 kW
    6. Create: The combustion chamber #3610574
      Value: Open
    7. Create: Efficiency #3610575
      Value: 91.1 %
    8. Create: Control #3610576
      Value: Electronic
    9. Create: Installation #3610577
      Value: Wall-mounted
    10. Create: Mains voltage #3610578
      Value: Single-phase
    11. Create: Peculiarities #3610579
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3610580
      Value: 6 l
    13. Create: Equipment #3610581
      Value: Display
    14. Create: Fuel #3610582
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3610583
      Value: 2.74 cu. m/hour
    16. Create: Nominal pressure of natural gas #3610584
      Value: 20 - 29 mbar
    17. Create: Permissible LPG pressure #3610585
      Value: 37 mbar
    18. Create: Heat carrier temperature #3610586
      Value: 35 - 80 °С
    19. Create: Temperature in the DHW circuit #3610587
      Value: 35 - 55 °С
    20. Create: Hot water capacity at t 30°C #3610588
      Value: 10.4 l/min
    21. Create: Max. water pressure in the DHW circuit #3610589
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3610590
      Value: 3 bar
    23. Create: Gas connection #3610591
      Value: 3/4"
    24. Create: Heating circuit connection #3610592
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3610593
      Value: 1/2"
    26. Create: Chimney diameter #3610594
      Value: 130 mm
    27. Create: Dimensions WxHxD #3610595
      Value: 440x751x240mm
    28. Create: Weight #3610596
      Value: 246 kg
    29. Create: Image #6358808
      URL: https://avatars.mds.yandex.net/get-mpic/4372959/img_id1109119770621641122.jpeg/orig
    30. Create: Preview image #6358809
      URL: https://avatars.mds.yandex.net/get-mpic/4372959/img_id1109119770621641122.jpeg/orig
  2. Donny Darko 30 April 2023 09:17:35
    Name: Gas boiler Alpha CB 24 TN 23.6 kW double-circuit; Catalog: Heating boilers