Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 14:13:19
Create:
Description #3604545
Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3604546
Value: Gas, convection
Create:
Burner #3604547
Value: Gas
Create:
Number of circuits #3604548
Value: Double-circuit
Create:
Thermal power #3604549
Value: 9.30 - 23.80 kW
Create:
Thermal load #3604550
Value: 10.50 - 25.70 kW
Create:
The combustion chamber #3604551
Value: Closed
Create:
Efficiency #3604552
Value: 92.9 %
Create:
Control #3604553
Value: Electronic
Create:
Installation #3604554
Value: Wall-mounted
Create:
Primary heat exchanger material #3604555
Value: Copper
Create:
Secondary heat exchanger material #3604556
Value: Stainless steel
Create:
Mains voltage #3604557
Value: Single-phase
Create:
Peculiarities #3604558
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve
Create:
Expansion tank volume #3604559
Value: 7 l
Create:
Equipment #3604560
Value: Built-in exhaust fan, display
Create:
Fuel #3604561
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3604562
Value: 2.7 cu. m/hour
Create:
LPG consumption #3604563
Value: 1.88 kg/h
Create:
Nominal pressure of natural gas #3604564
Value: 20 mbar
Create:
Permissible LPG pressure #3604565
Value: 37 mbar
Create:
Heat carrier temperature #3604566
Value: 35 - 85 °С
Create:
Temperature in the DHW circuit #3604567
Value: 35 - 55 °С
Create:
Hot water capacity at t 30°C #3604568
Value: 10.2 l/min
Create:
Max. water pressure in the DHW circuit #3604569
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3604570
Value: 3 bar
Create:
Gas connection #3604571
Value: 3/4"
Create:
Heating circuit connection #3604572
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3604573
Value: 1/2"
Create:
Coaxial chimney diameter #3604574
Value: 60/100 mm
Create:
Dimensions WxHxD #3604575
Value: 403x733x329 mm
Create:
Weight #3604576
Value: 31 kg
Create:
Additional Information #3604577
Value: Degree of electrical protection X5D
Create:
Image #6357818
URL: https://avatars.mds.yandex.net/get-mpic/4408567/img_id4832046623946840515.jpeg/orig
Create:
Image #6357819
URL: https://avatars.mds.yandex.net/get-mpic/7179065/img_id1382022508957983588.jpeg/orig
Create:
Image #6357820
URL: https://avatars.mds.yandex.net/get-mpic/7505748/img_id3057363385918606304.jpeg/orig
Create:
Image #6357821
URL: https://avatars.mds.yandex.net/get-mpic/6879515/img_id8512309349106344691.jpeg/orig
Create:
Image #6357822
URL: https://avatars.mds.yandex.net/get-mpic/6175580/img_id8076809273220599755.png/orig
Create:
Image #6357823
URL: https://avatars.mds.yandex.net/get-mpic/5217690/img_id4988015354926731408.jpeg/orig
Create:
Image #6357824
URL: https://avatars.mds.yandex.net/get-mpic/5194541/img_id1719738553436616776.jpeg/orig
Create:
Image #6357825
URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id6589325274586456431.jpeg/orig
Create:
Image #6357826
URL: https://avatars.mds.yandex.net/get-mpic/4399094/img_id3038458494967667099.jpeg/orig
Create:
Image #6357827
URL: https://avatars.mds.yandex.net/get-mpic/5210428/img_id3415530948125150103.jpeg/orig
Create:
Image #6357828
URL: https://avatars.mds.yandex.net/get-mpic/6259165/img_id6186821111054013539.jpeg/orig
Create:
Image #6357829
URL: https://avatars.mds.yandex.net/get-mpic/6253235/img_id6710186833741543953.png/orig
Create:
Image #6357830
URL: https://avatars.mds.yandex.net/get-mpic/5256749/img_id5167134869581894835.jpeg/orig
Create:
Image #6357831
URL: https://avatars.mds.yandex.net/get-mpic/3934197/img_id5893895596576405813.jpeg/orig
Create:
Preview image #6357832
URL: https://avatars.mds.yandex.net/get-mpic/4408567/img_id4832046623946840515.jpeg/orig
Donny Darko 30 April 2023 09:16:04
Name: Gas Hi-Therm Optimus 24 double-circuit; Catalog: Heating boilers