Change history for item: Gas Hi-Therm Optimus 12 double-circuit

  1. Donny Darko 09 July 2023 14:13:13
    1. Create: Description #3604514
      Value: Type of heating boiler: gas, max. heating power: 12.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3604515
      Value: Gas, convection
    3. Create: Burner #3604516
      Value: Gas
    4. Create: Number of circuits #3604517
      Value: Double-circuit
    5. Create: Thermal power #3604518
      Value: 9.30 - 12.20 kW
    6. Create: The combustion chamber #3604519
      Value: Closed
    7. Create: Efficiency #3604520
      Value: 92.9 %
    8. Create: Control #3604521
      Value: Electronic
    9. Create: Installation #3604522
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3604523
      Value: Copper
    11. Create: Secondary heat exchanger material #3604524
      Value: Stainless steel
    12. Create: Mains voltage #3604525
      Value: Single-phase
    13. Create: Peculiarities #3604526
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve
    14. Create: Expansion tank volume #3604527
      Value: 7 l
    15. Create: Equipment #3604528
      Value: Built-in exhaust fan, display
    16. Create: Fuel #3604529
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3604530
      Value: 1.48 cu. m/hour
    18. Create: LPG consumption #3604531
      Value: 1.02 kg/hour
    19. Create: Nominal pressure of natural gas #3604532
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3604533
      Value: 37 mbar
    21. Create: Heat carrier temperature #3604534
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3604535
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 30°C #3604536
      Value: 10.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3604537
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3604538
      Value: 3 bar
    26. Create: Gas connection #3604539
      Value: 3/4"
    27. Create: Heating circuit connection #3604540
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3604541
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3604542
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3604543
      Value: 403x730x345mm
    31. Create: Weight #3604544
      Value: 31 kg
    32. Create: Image #6357810
      URL: https://avatars.mds.yandex.net/get-mpic/3749045/img_id32634123507722799.jpeg/orig
    33. Create: Image #6357811
      URL: https://avatars.mds.yandex.net/get-mpic/1927699/img_id8543030634445552986.jpeg/orig
    34. Create: Image #6357812
      URL: https://avatars.mds.yandex.net/get-mpic/5210428/img_id3415530948125150103.jpeg/orig
    35. Create: Image #6357813
      URL: https://avatars.mds.yandex.net/get-mpic/6253235/img_id6710186833741543953.png/orig
    36. Create: Image #6357814
      URL: https://avatars.mds.yandex.net/get-mpic/6259165/img_id6186821111054013539.jpeg/orig
    37. Create: Image #6357815
      URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id5175634103563659170.png/orig
    38. Create: Image #6357816
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id4985556596354633248.jpeg/orig
    39. Create: Preview image #6357817
      URL: https://avatars.mds.yandex.net/get-mpic/3749045/img_id32634123507722799.jpeg/orig
  2. Donny Darko 30 April 2023 09:16:04
    Name: Gas Hi-Therm Optimus 12 double-circuit; Catalog: Heating boilers