Change history for item: Gas Hi-Therm Matrix 35 double-circuit

  1. Donny Darko 09 July 2023 14:12:32
    1. Create: Description #3604299
      Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3604300
      Value: Gas, condensing
    3. Create: Burner #3604301
      Value: Gas
    4. Create: Number of circuits #3604302
      Value: Double-circuit
    5. Create: Thermal power #3604303
      Value: 8.10 - 35 kW
    6. Create: Thermal load #3604304
      Value: 9 - 35.90 kW
    7. Create: The combustion chamber #3604305
      Value: Closed
    8. Create: Efficiency #3604306
      Value: 107.5 %
    9. Create: Control #3604307
      Value: Electronic
    10. Create: Installation #3604308
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3604309
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3604310
      Value: Stainless steel
    13. Create: Mains voltage #3604311
      Value: Single-phase
    14. Create: Peculiarities #3604312
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    15. Create: Expansion tank volume #3604313
      Value: 8 l
    16. Create: Equipment #3604314
      Value: Built-in exhaust fan, display
    17. Create: Fuel #3604315
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3604316
      Value: 3.79 cu. m/hour
    19. Create: LPG consumption #3604317
      Value: 2.87 kg/h
    20. Create: Nominal pressure of natural gas #3604318
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3604319
      Value: 37 mbar
    22. Create: Heat carrier temperature #3604320
      Value: 30 - 80 °С
    23. Create: Temperature in the DHW circuit #3604321
      Value: 30 - 65 °С
    24. Create: Max. water pressure in the DHW circuit #3604322
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3604323
      Value: 3 bar
    26. Create: Gas connection #3604324
      Value: 3/4"
    27. Create: Heating circuit connection #3604325
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3604326
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3604327
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3604328
      Value: Yes
    31. Create: Dimensions WxHxD #3604329
      Value: 410x678x288mm
    32. Create: Weight #3604330
      Value: 32 kg
    33. Create: Image #6357790
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id2244136141394235373.jpeg/orig
    34. Create: Image #6357791
      URL: https://avatars.mds.yandex.net/get-mpic/4794494/img_id165867512465538801.jpeg/orig
    35. Create: Image #6357792
      URL: https://avatars.mds.yandex.net/get-mpic/1926869/img_id654024902475080215.jpeg/orig
    36. Create: Preview image #6357793
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id2244136141394235373.jpeg/orig
  2. Donny Darko 30 April 2023 09:16:01
    Name: Gas Hi-Therm Matrix 35 double-circuit; Catalog: Heating boilers