      Value: Type of heating boiler: gas, max. thermal power: 27.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3604222
      Value: Gas, convection
    3. Create: Burner #3604223
      Value: Gas
    4. Create: Number of circuits #3604224
      Value: Double-circuit
    5. Create: Thermal power #3604225
      Value: 10.30 - 27.80 kW
    6. Create: The combustion chamber #3604226
      Value: Closed
    7. Create: Efficiency #3604227
      Value: 90.4 %
    8. Create: Control #3604228
      Value: Electronic
    9. Create: Installation #3604229
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3604230
      Value: Copper
    11. Create: Secondary heat exchanger material #3604231
      Value: Stainless steel
    12. Create: Mains voltage #3604232
      Value: Single-phase
    13. Create: Peculiarities #3604233
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve
    14. Create: Expansion tank volume #3604234
      Value: 7 l
    15. Create: Equipment #3604235
      Value: Built-in exhaust fan, display
    16. Create: Fuel #3604236
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3604237
      Value: 3.1 cu. m/hour
    18. Create: LPG consumption #3604238
      Value: 2.15 kg/hour
    19. Create: Nominal pressure of natural gas #3604239
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3604240
      Value: 37 mbar
    21. Create: Heat carrier temperature #3604241
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3604242
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 30°C #3604243
      Value: 12.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3604244
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3604245
      Value: 3 bar
    26. Create: Gas connection #3604246
      Value: 3/4"
    27. Create: Heating circuit connection #3604247
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3604248
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3604249
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3604250
      Value: 403x730x345mm
    31. Create: Weight #3604251
      Value: 31 kg
    32. Create: Image #6357784
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7510929168894520065.jpeg/orig
    33. Create: Preview image #6357785
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7510929168894520065.jpeg/orig
  2. Donny Darko 30 April 2023 09:16:01
    Name: Gas Hi-Therm Optimus 28 double-circuit; Catalog: Heating boilers