Change history for item: Gas Hi-Therm Optimus 18 double-circuit

  1. Donny Darko 09 July 2023 14:11:02
    1. Create: Description #3603840
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3603841
      Value: Gas, convection
    3. Create: Burner #3603842
      Value: Gas
    4. Create: Number of circuits #3603843
      Value: Double-circuit
    5. Create: Thermal power #3603844
      Value: 9.30 - 18 kW
    6. Create: The combustion chamber #3603845
      Value: Closed
    7. Create: Efficiency #3603846
      Value: 92.9 %
    8. Create: Control #3603847
      Value: Electronic
    9. Create: Installation #3603848
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3603849
      Value: Copper
    11. Create: Secondary heat exchanger material #3603850
      Value: Stainless steel
    12. Create: Mains voltage #3603851
      Value: Single-phase
    13. Create: Peculiarities #3603852
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve
    14. Create: Expansion tank volume #3603853
      Value: 7 l
    15. Create: Equipment #3603854
      Value: Built-in exhaust fan, display
    16. Create: Fuel #3603855
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3603856
      Value: 2.07 cu. m/hour
    18. Create: LPG consumption #3603857
      Value: 1.3 kg/hour
    19. Create: Nominal pressure of natural gas #3603858
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3603859
      Value: 37 mbar
    21. Create: Heat carrier temperature #3603860
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3603861
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 30°C #3603862
      Value: 10.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3603863
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3603864
      Value: 3 bar
    26. Create: Gas connection #3603865
      Value: 3/4"
    27. Create: Heating circuit connection #3603866
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3603867
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3603868
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3603869
      Value: 403x730x345mm
    31. Create: Weight #3603870
      Value: 31 kg
    32. Create: Image #6357736
      URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id1625829880823065768.jpeg/orig
    33. Create: Image #6357737
      URL: https://avatars.mds.yandex.net/get-mpic/5280669/img_id7881842087468621949.jpeg/orig
    34. Create: Image #6357738
      URL: https://avatars.mds.yandex.net/get-mpic/5256749/img_id5167134869581894835.jpeg/orig
    35. Create: Image #6357739
      URL: https://avatars.mds.yandex.net/get-mpic/5210428/img_id3415530948125150103.jpeg/orig
    36. Create: Image #6357740
      URL: https://avatars.mds.yandex.net/get-mpic/6253235/img_id6710186833741543953.png/orig
    37. Create: Image #6357741
      URL: https://avatars.mds.yandex.net/get-mpic/6259165/img_id6186821111054013539.jpeg/orig
    38. Create: Image #6357742
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id4985556596354633248.jpeg/orig
    39. Create: Preview image #6357743
      URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id1625829880823065768.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:56
    Name: Gas Hi-Therm Optimus 18 double-circuit; Catalog: Heating boilers