Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 14:01:09
Create:
Width #34669
Value: 400
Create:
Height #34670
Value: 700
Create:
Description #3602760
Value: Type of heating boiler: gas, max. heating power: 25.70 kW, number of circuits: double-circuit, location: floor/wall, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: about
Create:
Type of heating boiler #3602761
Value: Gas
Create:
Number of circuits #3602762
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3602763
Value: Convection
Create:
Combustion chamber type #3602764
Value: Open
Create:
Primary heat exchanger material #3602765
Value: Copper
Create:
Accommodation #3602766
Value: Floor/wall
Create:
Power type #3602767
Value: Single-phase
Create:
Functions #3602768
Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
Create:
Minimum heat output #3602769
Value: 10 kW
Create:
Max. thermal power #3602770
Value: 25.7 kW
Create:
Minimum heat load #3602771
Value: 10 kW
Create:
Maximum thermal load #3602772
Value: 25.7 kW
Create:
Efficiency #3602773
Value: 90.9 %
Create:
Heated area #3602774
Value: 260 m²
Create:
Maximum water pressure in the heating circuit #3602775
Value: 3 bar
Create:
Minimum heating medium temperature #3602776
Value: 35°C
Create:
Maximum coolant temperature #3602777
Value: 85°C
Create:
Expansion tank volume #3602778
Value: 8 l
Create:
Gas connection #3602779
Value: 3/4"
Create:
Heating circuit connection #3602780
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3602781
Value: 1/2"
Create:
Chimney diameter #3602782
Value: 130 mm
Create:
Burner #3602783
Value: Gas
Create:
Secondary heat exchanger material #3602784
Value: Stainless steel
Create:
Minimum temperature in the DHW circuit #3602785
Value: 35°C
Create:
Maximum temperature in the DHW circuit #3602786
Value: 55°C
Create:
Maximum water pressure in the DHW circuit #3602787
Value: 6 bar
Create:
Fuel for automatic feeding #3602788
Value: Gas
Create:
Fuel #3602789
Value: Natural gas, liquefied gas
Create:
Depth #3602790
Value: 300 mm
Create:
Image #6357613
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id9135702246638585947.jpeg/orig
Create:
Image #6357614
URL: https://avatars.mds.yandex.net/get-mpic/7690783/img_id4848028558537726808.jpeg/orig
Create:
Image #6357615
URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id2085622697112889817.jpeg/orig
Create:
Image #6357616
URL: https://avatars.mds.yandex.net/get-mpic/7980098/img_id5464242029978493076.jpeg/orig
Create:
Image #6357617
URL: https://avatars.mds.yandex.net/get-mpic/5167413/img_id121198081536188731.jpeg/orig
Create:
Image #6357618
URL: https://avatars.mds.yandex.net/get-mpic/5304975/img_id5311722009877512079.jpeg/orig
Create:
Preview image #6357619
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id9135702246638585947.jpeg/orig
Donny Darko 30 April 2023 09:15:31
Name: Double-circuit Italtherm City Class 24 C 25.7 kW + Stabilizer for gas boiler VOTO TM-500VA; Catalog: Heating boilers