Change history for item: Double-circuit Italtherm City Class 40 F 39.5 kW + Stabilizer for gas boiler VOTO TM-500VA

  1. Donny Darko 09 July 2023 16:46:16
    1. Create: Width #34824
      Value: 400
    2. Create: Height #34825
      Value: 727
    3. Create: Description #3627369
      Value: Type of heating boiler: gas, max. heating power: 39.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    4. Create: Type of heating boiler #3627370
      Value: Gas
    5. Create: Number of circuits #3627371
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3627372
      Value: Convection
    7. Create: Combustion chamber type #3627373
      Value: Closed
    8. Create: Primary heat exchanger material #3627374
      Value: Copper
    9. Create: Accommodation #3627375
      Value: Wall
    10. Create: Power type #3627376
      Value: Single-phase
    11. Create: Control #3627377
      Value: Electronic
    12. Create: Equipment #3627378
      Value: Built-in exhaust fan
    13. Create: Functions #3627379
      Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
    14. Create: Minimum heat output #3627380
      Value: 12 kW
    15. Create: Max. thermal power #3627381
      Value: 39.5 kW
    16. Create: Minimum heat load #3627382
      Value: 12 kW
    17. Create: Maximum thermal load #3627383
      Value: 39.5 kW
    18. Create: Efficiency #3627384
      Value: 91.9 %
    19. Create: Heated area #3627385
      Value: 400 m²
    20. Create: Maximum water pressure in the heating circuit #3627386
      Value: 3 bar
    21. Create: Minimum heating medium temperature #3627387
      Value: 35°C
    22. Create: Maximum coolant temperature #3627388
      Value: 85°C
    23. Create: Expansion tank volume #3627389
      Value: 10 l
    24. Create: Gas connection #3627390
      Value: 3/4"
    25. Create: Heating circuit connection #3627391
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3627392
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3627393
      Value: 60/100 mm
    28. Create: Burner #3627394
      Value: Gas
    29. Create: Fuel for automatic feeding #3627395
      Value: Gas
    30. Create: Fuel #3627396
      Value: Natural gas, liquefied gas
    31. Create: Hot water capacity at t 25°C #3627397
      Value: 20.3 l/min
    32. Create: Depth #3627398
      Value: 324 mm
    33. Create: Image #6362500
      URL: https://avatars.mds.yandex.net/get-mpic/7377109/img_id8096895039613157398.jpeg/orig
    34. Create: Image #6362501
      URL: https://avatars.mds.yandex.net/get-mpic/7631329/img_id8473391038215925026.jpeg/orig
    35. Create: Image #6362502
      URL: https://avatars.mds.yandex.net/get-mpic/7552302/img_id2437049467877822515.jpeg/orig
    36. Create: Image #6362503
      URL: https://avatars.mds.yandex.net/get-mpic/7394206/img_id5324858917437854216.jpeg/orig
    37. Create: Preview image #6362504
      URL: https://avatars.mds.yandex.net/get-mpic/7377109/img_id8096895039613157398.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:30
    Name: Double-circuit Italtherm City Class 40 F 39.5 kW + Stabilizer for gas boiler VOTO TM-500VA; Catalog: Heating boilers