Change history for item: Double-circuit Italtherm City Class 28 С 28.3 kW + Stabilizer for gas boiler VOTO TM-500VA

  1. Donny Darko 09 July 2023 14:00:25
    1. Create: Width #34661
      Value: 400
    2. Create: Height #34662
      Value: 700
    3. Create: Description #3602621
      Value: Type of heating boiler: gas, max. heating power: 28.30 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    4. Create: Type of heating boiler #3602622
      Value: Gas
    5. Create: Number of circuits #3602623
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3602624
      Value: Convection
    7. Create: Combustion chamber type #3602625
      Value: Open
    8. Create: Primary heat exchanger material #3602626
      Value: Copper
    9. Create: Accommodation #3602627
      Value: Wall
    10. Create: Non-volatile #3602628
      Value: There is
    11. Create: Power type #3602629
      Value: Single-phase
    12. Create: Control #3602630
      Value: Electronic
    13. Create: Equipment #3602631
      Value: Built-in exhaust fan
    14. Create: Functions #3602632
      Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
    15. Create: Minimum heat output #3602633
      Value: 10 kW
    16. Create: Max. thermal power #3602634
      Value: 28.3 kW
    17. Create: Minimum heat load #3602635
      Value: 10 kW
    18. Create: Maximum thermal load #3602636
      Value: 28.3 kW
    19. Create: Efficiency #3602637
      Value: 91.9 %
    20. Create: Heated area #3602638
      Value: 280 m²
    21. Create: Maximum water pressure in the heating circuit #3602639
      Value: 3 bar
    22. Create: Minimum heating medium temperature #3602640
      Value: 35°C
    23. Create: Maximum coolant temperature #3602641
      Value: 85°C
    24. Create: Expansion tank volume #3602642
      Value: 8 l
    25. Create: Gas connection #3602643
      Value: 3/4"
    26. Create: Heating circuit connection #3602644
      Value: 3/4"
    27. Create: Chimney diameter #3602645
      Value: 140 mm
    28. Create: Coaxial chimney diameter #3602646
      Value: 60/100 mm
    29. Create: Burner #3602647
      Value: Gas
    30. Create: Secondary heat exchanger material #3602648
      Value: Stainless steel
    31. Create: Minimum temperature in the DHW circuit #3602649
      Value: 35°C
    32. Create: Maximum temperature in the DHW circuit #3602650
      Value: 55°C
    33. Create: Maximum water pressure in the DHW circuit #3602651
      Value: 6 bar
    34. Create: Fuel for automatic feeding #3602652
      Value: Gas
    35. Create: Fuel #3602653
      Value: Natural gas, liquefied gas
    36. Create: Hot water capacity at t 25°C #3602654
      Value: 13.3 l/min
    37. Create: Depth #3602655
      Value: 300 mm
    38. Create: Image #6357588
      URL: https://avatars.mds.yandex.net/get-mpic/7394206/img_id9040513393620930579.jpeg/orig
    39. Create: Image #6357589
      URL: https://avatars.mds.yandex.net/get-mpic/6259165/img_id7234454420812171398.jpeg/orig
    40. Create: Image #6357590
      URL: https://avatars.mds.yandex.net/get-mpic/7543961/img_id803290925226382877.jpeg/orig
    41. Create: Image #6357591
      URL: https://avatars.mds.yandex.net/get-mpic/7547374/img_id6374746308402764282.jpeg/orig
    42. Create: Image #6357592
      URL: https://avatars.mds.yandex.net/get-mpic/7400882/img_id7512421341576281377.jpeg/orig
    43. Create: Image #6357593
      URL: https://avatars.mds.yandex.net/get-mpic/7467475/img_id6323024793528789124.jpeg/orig
    44. Create: Preview image #6357594
      URL: https://avatars.mds.yandex.net/get-mpic/7394206/img_id9040513393620930579.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:30
    Name: Double-circuit Italtherm City Class 28 С 28.3 kW + Stabilizer for gas boiler VOTO TM-500VA; Catalog: Heating boilers