Change history for item: Double-circuit Italtherm City Class 12 F 13.8kW + Voltage stabilizer wall-mounted BOILER 0.5 kVA IEK

  1. Donny Darko 09 July 2023 14:00:14
    1. Create: Width #34657
      Value: 400
    2. Create: Height #34658
      Value: 700
    3. Create: Description #3602557
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    4. Create: Type of heating boiler #3602558
      Value: Gas
    5. Create: Number of circuits #3602559
      Value: Double-sided, single-sided
    6. Create: The principle of operation of a liquid fuel boiler #3602560
      Value: Classical
    7. Create: The principle of operation of a solid fuel boiler #3602561
      Value: Classical
    8. Create: Combustion chamber type #3602562
      Value: Closed
    9. Create: Primary heat exchanger material #3602563
      Value: Copper
    10. Create: Accommodation #3602564
      Value: Wall
    11. Create: Non-volatile #3602565
      Value: There is
    12. Create: Power type #3602566
      Value: Single-phase
    13. Create: Control #3602567
      Value: Electronic
    14. Create: Equipment #3602568
      Value: Built-in exhaust fan
    15. Create: Functions #3602569
      Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
    16. Create: Minimum heat output #3602570
      Value: 10 kW
    17. Create: Max. thermal power #3602571
      Value: 13.8 kW
    18. Create: Minimum heat load #3602572
      Value: 10 kW
    19. Create: Maximum thermal load #3602573
      Value: 13.8 kW
    20. Create: Efficiency #3602574
      Value: 91.9 %
    21. Create: Heated area #3602575
      Value: 140 m²
    22. Create: Maximum water pressure in the heating circuit #3602576
      Value: 3 bar
    23. Create: Minimum heating medium temperature #3602577
      Value: 35°C
    24. Create: Maximum coolant temperature #3602578
      Value: 85°C
    25. Create: Expansion tank volume #3602579
      Value: 8 l
    26. Create: Gas connection #3602580
      Value: 3/4"
    27. Create: Heating circuit connection #3602581
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3602582
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3602583
      Value: 60/100 mm
    30. Create: Burner #3602584
      Value: Gas
    31. Create: Secondary heat exchanger material #3602585
      Value: Stainless steel
    32. Create: Minimum temperature in the DHW circuit #3602586
      Value: 35°C
    33. Create: Maximum temperature in the DHW circuit #3602587
      Value: 55°C
    34. Create: Maximum water pressure in the DHW circuit #3602588
      Value: 6 bar
    35. Create: Fuel for automatic feeding #3602589
      Value: Gas
    36. Create: Fuel #3602590
      Value: Natural gas, liquefied gas
    37. Create: Hot water capacity at t 25°C #3602591
      Value: 13.7 l/min
    38. Create: Depth #3602592
      Value: 300 mm
    39. Create: Image #6357571
      URL: https://avatars.mds.yandex.net/get-mpic/7726747/img_id229154074644124886.jpeg/orig
    40. Create: Image #6357572
      URL: https://avatars.mds.yandex.net/get-mpic/7471903/img_id8827006593912040548.jpeg/orig
    41. Create: Image #6357573
      URL: https://avatars.mds.yandex.net/get-mpic/7979862/img_id3840087549266567407.jpeg/orig
    42. Create: Image #6357574
      URL: https://avatars.mds.yandex.net/get-mpic/4956986/img_id3660601784745398304.jpeg/orig
    43. Create: Image #6357575
      URL: https://avatars.mds.yandex.net/get-mpic/4887838/img_id2909246481508111405.jpeg/orig
    44. Create: Image #6357576
      URL: https://avatars.mds.yandex.net/get-mpic/7666641/img_id3803716555107923064.jpeg/orig
    45. Create: Image #6357577
      URL: https://avatars.mds.yandex.net/get-mpic/6458782/img_id8924035234894803400.jpeg/orig
    46. Create: Image #6357578
      URL: https://avatars.mds.yandex.net/get-mpic/7980765/img_id5343904122377458496.png/orig
    47. Create: Image #6357579
      URL: https://avatars.mds.yandex.net/get-mpic/6263631/img_id7959270633816844940.jpeg/orig
    48. Create: Preview image #6357580
      URL: https://avatars.mds.yandex.net/get-mpic/7726747/img_id229154074644124886.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:29
    Name: Double-circuit Italtherm City Class 12 F 13.8kW + Voltage stabilizer wall-mounted BOILER 0.5 kVA IEK; Catalog: Heating boilers