Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 13:59:41
Create:
Width #34645
Value: 400
Create:
Height #34646
Value: 700
Create:
Description #3602366
Value: Type of heating boiler: gas, max. heating power: 34.50 kW, number of circuits: single-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3602367
Value: Gas
Create:
Number of circuits #3602368
Value: Single-loop
Create:
The principle of operation of a gas boiler #3602369
Value: Convection
Create:
Combustion chamber type #3602370
Value: Closed
Create:
Primary heat exchanger material #3602371
Value: Stainless steel
Create:
Accommodation #3602372
Value: Wall
Create:
Non-volatile #3602373
Value: There is
Create:
Power type #3602374
Value: Single-phase
Create:
Equipment #3602375
Value: Built-in exhaust fan
Create:
Functions #3602376
Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
Create:
Minimum heat output #3602377
Value: 10 kW
Create:
Max. thermal power #3602378
Value: 34.5 kW
Create:
Minimum heat load #3602379
Value: 10 kW
Create:
Maximum thermal load #3602380
Value: 34.5 kW
Create:
Efficiency #3602381
Value: 91.9 %
Create:
Heated area #3602382
Value: 350 m²
Create:
Maximum water pressure in the heating circuit #3602383
Value: 6 bar
Create:
Minimum heating medium temperature #3602384
Value: 35°C
Create:
Maximum coolant temperature #3602385
Value: 85°C
Create:
Gas connection #3602386
Value: 3/4"
Create:
Heating circuit connection #3602387
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3602388
Value: 1/2"
Create:
Coaxial chimney diameter #3602389
Value: 60/100 mm
Create:
Burner #3602390
Value: Gas
Create:
Fuel for automatic feeding #3602391
Value: Gas
Create:
Fuel #3602392
Value: Natural gas, liquefied gas
Create:
Depth #3602393
Value: 300 mm
Create:
Image #6357524
URL: https://avatars.mds.yandex.net/get-mpic/7658228/img_id1085210502334860364.jpeg/orig
Create:
Image #6357525
URL: https://avatars.mds.yandex.net/get-mpic/7631660/img_id6375183162429122193.jpeg/orig
Create:
Image #6357526
URL: https://avatars.mds.yandex.net/get-mpic/5220030/img_id2507290923584648624.jpeg/orig
Create:
Image #6357527
URL: https://avatars.mds.yandex.net/get-mpic/7724829/img_id7797813826491678471.jpeg/orig
Create:
Image #6357528
URL: https://avatars.mds.yandex.net/get-mpic/7937668/img_id1162795704505368242.jpeg/orig
Create:
Image #6357529
URL: https://avatars.mds.yandex.net/get-mpic/6367278/img_id399360393931734124.jpeg/orig
Create:
Image #6357530
URL: https://avatars.mds.yandex.net/get-mpic/7888310/img_id2515340495483142752.png/orig
Create:
Preview image #6357531
URL: https://avatars.mds.yandex.net/get-mpic/7658228/img_id1085210502334860364.jpeg/orig
Donny Darko 30 April 2023 09:15:27
Name: Single-circuit Italtherm City Class 35 FR 34.5 kW + Voltage stabilizer wall-mounted BOILER 0.5 kVA IEK; Catalog: Heating boilers