    1. Create: Width #34639
      Value: 400
    2. Create: Height #34640
      Value: 700
    3. Create: Description #3602270
      Value: Type of heating boiler: gas, max. heating power: 28.30 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    4. Create: Type of heating boiler #3602271
      Value: Gas
    5. Create: Number of circuits #3602272
      Value: Double-circuit
    6. Create: The principle of operation of an electric boiler #3602273
      Value: Electrode
    7. Create: Combustion chamber type #3602274
      Value: Open
    8. Create: Primary heat exchanger material #3602275
      Value: Copper
    9. Create: Accommodation #3602276
      Value: Wall
    10. Create: Power type #3602277
      Value: Single-phase
    11. Create: Control #3602278
      Value: Electronic
    12. Create: Functions #3602279
      Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
    13. Create: Minimum heat output #3602280
      Value: 10 kW
    14. Create: Max. thermal power #3602281
      Value: 28.3 kW
    15. Create: Minimum heat load #3602282
      Value: 10 kW
    16. Create: Maximum thermal load #3602283
      Value: 28.3 kW
    17. Create: Efficiency #3602284
      Value: 90.9 %
    18. Create: Heated area #3602285
      Value: 280 m²
    19. Create: Maximum water pressure in the heating circuit #3602286
      Value: 3 bar
    20. Create: Minimum heating medium temperature #3602287
      Value: 35°C
    21. Create: Maximum coolant temperature #3602288
      Value: 85°C
    22. Create: Gas connection #3602289
      Value: 3/4"
    23. Create: Heating circuit connection #3602290
      Value: 3/4"
    24. Create: Branch pipe for connecting the DHW circuit #3602291
      Value: 1/2"
    25. Create: Chimney diameter #3602292
      Value: 140 mm
    26. Create: Burner #3602293
      Value: Gas
    27. Create: Minimum temperature in the DHW circuit #3602294
      Value: 35°C
    28. Create: Maximum temperature in the DHW circuit #3602295
      Value: 55°C
    29. Create: Maximum water pressure in the DHW circuit #3602296
      Value: 6 bar
    30. Create: Fuel for automatic feeding #3602297
      Value: Gas
    31. Create: Fuel #3602298
      Value: Natural gas, liquefied gas
    32. Create: Depth #3602299
      Value: 300 mm
    33. Create: Image #6357497
      URL: https://avatars.mds.yandex.net/get-mpic/7473874/img_id5814063630422450996.jpeg/orig
    34. Create: Image #6357498
      URL: https://avatars.mds.yandex.net/get-mpic/7754338/img_id3704001367073554875.jpeg/orig
    35. Create: Image #6357499
      URL: https://avatars.mds.yandex.net/get-mpic/7754338/img_id9022829091162701717.jpeg/orig
    36. Create: Image #6357500
      URL: https://avatars.mds.yandex.net/get-mpic/7721969/img_id7015062294976457657.jpeg/orig
    37. Create: Image #6357501
      URL: https://avatars.mds.yandex.net/get-mpic/7979270/img_id8199407897691764916.jpeg/orig
    38. Create: Image #6357502
      URL: https://avatars.mds.yandex.net/get-mpic/7728649/img_id8850293610824695096.jpeg/orig
    39. Create: Image #6357503
      URL: https://avatars.mds.yandex.net/get-mpic/7764504/img_id3526208235377696287.png/orig
    40. Create: Image #6357504
      URL: https://avatars.mds.yandex.net/get-mpic/7552302/img_id6721461706393420180.jpeg/orig
    41. Create: Preview image #6357505
      URL: https://avatars.mds.yandex.net/get-mpic/7473874/img_id5814063630422450996.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:26
    Name: Double-circuit Italtherm City Class 28 С 28.3kW + Voltage stabilizer wall-mounted BOILER 0.5 kVA IEK; Catalog: Heating boilers