Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 13:56:20
Create:
Width #34599
Value: 400
Create:
Height #34600
Value: 700
Create:
Description #3601570
Value: Type of heating boiler: gas, max. thermal power: 21 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3601571
Value: Gas
Create:
Number of circuits #3601572
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3601573
Value: Convection
Create:
Combustion chamber type #3601574
Value: Closed
Create:
Primary heat exchanger material #3601575
Value: Copper
Create:
Accommodation #3601576
Value: Wall
Create:
Power type #3601577
Value: Single-phase
Create:
Control #3601578
Value: Electronic
Create:
Equipment #3601579
Value: Built-in exhaust fan
Create:
Functions #3601580
Value: Auto-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, underfloor heating connection, programmer, electric ignition
Create:
Minimum heat output #3601581
Value: 9.5 kW
Create:
Max. thermal power #3601582
Value: 21 kW
Create:
Minimum heat load #3601583
Value: 81 kW
Create:
Maximum thermal load #3601584
Value: 19.5 kW
Create:
Efficiency #3601585
Value: 92 %
Create:
Heated area #3601586
Value: 200 m²
Create:
Maximum water pressure in the heating circuit #3601587
Value: 3 bar
Create:
Minimum heating medium temperature #3601588
Value: 35°C
Create:
Maximum coolant temperature #3601589
Value: 80°C
Create:
Expansion tank volume #3601590
Value: 8 l
Create:
Gas connection #3601591
Value: 3/4"
Create:
Heating circuit connection #3601592
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3601593
Value: 1/2"
Create:
Coaxial chimney diameter #3601594
Value: 60/100 mm
Create:
Secondary heat exchanger material #3601595
Value: Stainless steel
Create:
Minimum temperature in the DHW circuit #3601596
Value: 35°C
Create:
Maximum temperature in the DHW circuit #3601597
Value: 55°C
Create:
Maximum water pressure in the DHW circuit #3601598
Value: 6 bar
Create:
Fuel #3601599
Value: Natural gas, liquefied gas
Create:
Hot water capacity at t 25°C #3601600
Value: 11.2 l/min
Create:
Hot water capacity at t 30°C #3601601
Value: 9.3 l/min
Create:
Natural gas consumption #3601602
Value: 2.22 m³/h
Create:
LPG consumption #3601603
Value: 1 kg/h
Create:
Depth #3601604
Value: 300 mm
Create:
Weight #3601605
Value: 304 kg
Create:
Image #6357278
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id8952264144637094935.png/orig
Create:
Image #6357279
URL: https://avatars.mds.yandex.net/get-mpic/5236090/img_id2255021559325770560.png/orig
Create:
Image #6357280
URL: https://avatars.mds.yandex.net/get-mpic/6439030/img_id4619753596381190366.png/orig
Create:
Image #6357281
URL: https://avatars.mds.yandex.net/get-mpic/1923922/img_id2293219651400601372.png/orig
Create:
Image #6357282
URL: https://avatars.mds.yandex.net/get-mpic/4407413/img_id932103666278279614.png/orig
Create:
Image #6357283
URL: https://avatars.mds.yandex.net/get-mpic/4322107/img_id7129603930374084343.png/orig
Create:
Image #6357284
URL: https://avatars.mds.yandex.net/get-mpic/1581127/img_id6668018227370636075.png/orig
Create:
Image #6357285
URL: https://avatars.mds.yandex.net/get-mpic/901948/img_id3240393619352405699.png/orig
Create:
Image #6357286
URL: https://avatars.mds.yandex.net/get-mpic/4956986/img_id102050159446532289.png/orig
Create:
Preview image #6357287
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id8952264144637094935.png/orig
Donny Darko 30 April 2023 09:15:19
Name: Double-circuit Italtherm City Class 20 F 21 kW + Chimney; Catalog: Heating boilers