Change history for item: Double-circuit condensing Italtherm City Class 30 K

  1. Donny Darko 09 July 2023 13:54:22
    1. Create: Description #3601091
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3601092
      Value: Gas
    3. Create: Number of circuits #3601093
      Value: Double-circuit
    4. Create: The principle of operation of a gas boiler #3601094
      Value: Condensing
    5. Create: Combustion chamber type #3601095
      Value: Closed
    6. Create: Primary heat exchanger material #3601096
      Value: Stainless steel
    7. Create: Accommodation #3601097
      Value: Wall
    8. Create: Non-volatile #3601098
      Value: There is
    9. Create: Power type #3601099
      Value: Single-phase
    10. Create: Control #3601100
      Value: Electronic
    11. Create: Equipment #3601101
      Value: Built-in exhaust fan
    12. Create: Functions #3601102
      Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, power-on indication, flame modulation, underfloor heating connection, programmer
    13. Create: Minimum heat output #3601103
      Value: 3 kW
    14. Create: Max. thermal power #3601104
      Value: 30 kW
    15. Create: Minimum heat load #3601105
      Value: 3 kW
    16. Create: Maximum thermal load #3601106
      Value: 30 kW
    17. Create: Efficiency #3601107
      Value: 106 %
    18. Create: Heated area #3601108
      Value: 300 m²
    19. Create: Maximum water pressure in the heating circuit #3601109
      Value: 3 bar
    20. Create: Minimum heating medium temperature #3601110
      Value: 20°C
    21. Create: Maximum coolant temperature #3601111
      Value: 80°C
    22. Create: Expansion tank volume #3601112
      Value: 8 l
    23. Create: Gas connection #3601113
      Value: 1/2"
    24. Create: Heating circuit connection #3601114
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3601115
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3601116
      Value: 60/100 mm
    27. Create: Separate chimney 80x80 mm #3601117
      Value: There is
    28. Create: Burner #3601118
      Value: Gas
    29. Create: Secondary heat exchanger material #3601119
      Value: Stainless steel
    30. Create: Bithermic heat exchanger #3601120
      Value: There is
    31. Create: Minimum temperature in the DHW circuit #3601121
      Value: 35°C
    32. Create: Maximum temperature in the DHW circuit #3601122
      Value: 55°C
    33. Create: Maximum water pressure in the DHW circuit #3601123
      Value: 6 bar
    34. Create: Fuel #3601124
      Value: Natural gas
    35. Create: Hot water capacity at t 25°C #3601125
      Value: 17.2 l/min
    36. Create: Hot water capacity at t 30°C #3601126
      Value: 13.8 l/min
    37. Create: Nominal natural gas pressure min. #3601127
      Value: 17 mbar
    38. Create: Nominal pressure of natural gas #3601128
      Value: 20 mbar
    39. Create: Permissible LPG pressure #3601129
      Value: 35 mbar
    40. Create: Depth #3601130
      Value: 325 mm
    41. Create: Image #6357102
      URL: https://avatars.mds.yandex.net/get-mpic/6382710/img_id6448598822912412163.png/orig
    42. Create: Preview image #6357103
      URL: https://avatars.mds.yandex.net/get-mpic/6382710/img_id6448598822912412163.png/orig
  2. Donny Darko 30 April 2023 09:15:15
    Name: Double-circuit condensing Italtherm City Class 30 K; Catalog: Heating boilers