Change history for item: Condensing Italtherm Time Power 160 K 150 kW

  1. Donny Darko 09 July 2023 16:38:31
    1. Create: Description #3626502
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3626503
      Value: Gas
    3. Create: Number of circuits #3626504
      Value: Single-loop
    4. Create: The principle of operation of a gas boiler #3626505
      Value: Condensing
    5. Create: Combustion chamber type #3626506
      Value: Closed
    6. Create: Primary heat exchanger material #3626507
      Value: Stainless steel
    7. Create: Accommodation #3626508
      Value: Wall
    8. Create: Non-volatile #3626509
      Value: There is
    9. Create: Power type #3626510
      Value: Single-phase
    10. Create: Control #3626511
      Value: Electronic
    11. Create: Equipment #3626512
      Value: Built-in exhaust fan
    12. Create: Functions #3626513
      Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, power-on indication, flame modulation, underfloor heating connection, programmer
    13. Create: Minimum heat output #3626514
      Value: 25 kW
    14. Create: Max. thermal power #3626515
      Value: 150 kW
    15. Create: Minimum heat load #3626516
      Value: 23.8 kW
    16. Create: Efficiency #3626517
      Value: 109.29 %
    17. Create: Heated area #3626518
      Value: 1500 m²
    18. Create: Maximum water pressure in the heating circuit #3626519
      Value: 4.5 bar
    19. Create: Minimum heating medium temperature #3626520
      Value: 20°C
    20. Create: Maximum coolant temperature #3626521
      Value: 78°C
    21. Create: Gas connection #3626522
      Value: 1"
    22. Create: Heating circuit connection #3626523
      Value: 1¼
    23. Create: Burner #3626524
      Value: Gas
    24. Create: Fuel #3626525
      Value: Natural gas, liquefied gas
    25. Create: Nominal natural gas pressure min. #3626526
      Value: 17 mbar
    26. Create: Nominal pressure of natural gas #3626527
      Value: 35 mbar
    27. Create: Permissible LPG pressure #3626528
      Value: 35 mbar
    28. Create: Natural gas consumption #3626529
      Value: 15.86 m³/h
    29. Create: LPG consumption #3626530
      Value: 11.63 kg/h
    30. Create: Depth #3626531
      Value: 725 mm
    31. Create: Weight #3626532
      Value: 108 kg
    32. Create: Image #6362379
      URL: https://avatars.mds.yandex.net/get-mpic/5226473/img_id6536814092243978760.jpeg/orig
    33. Create: Image #6362380
      URL: https://avatars.mds.yandex.net/get-mpic/5219306/img_id803115400250682527.jpeg/orig
    34. Create: Image #6362381
      URL: https://avatars.mds.yandex.net/get-mpic/4012462/img_id8403022893314438794.jpeg/orig
    35. Create: Image #6362382
      URL: https://avatars.mds.yandex.net/get-mpic/5227903/img_id235786375288991101.jpeg/orig
    36. Create: Image #6362383
      URL: https://avatars.mds.yandex.net/get-mpic/4303532/img_id3767810129058223356.jpeg/orig
    37. Create: Image #6362384
      URL: https://avatars.mds.yandex.net/get-mpic/4370207/img_id3400732644961138350.png/orig
    38. Create: Image #6362385
      URL: https://avatars.mds.yandex.net/get-mpic/4936002/img_id3918226378197368960.png/orig
    39. Create: Image #6362386
      URL: https://avatars.mds.yandex.net/get-mpic/1704691/img_id7979223718988444216.png/orig
    40. Create: Preview image #6362387
      URL: https://avatars.mds.yandex.net/get-mpic/5226473/img_id6536814092243978760.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:13
    Name: Condensing Italtherm Time Power 160 K 150 kW; Catalog: Heating boilers