Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 13:53:27
Create:
Non-volatile #3600905
Value: There is
Create:
Image #6357041
URL: https://avatars.mds.yandex.net/get-mpic/7543961/img_id8891118884022404896.png/orig
Create:
Image #6357042
URL: https://avatars.mds.yandex.net/get-mpic/1600461/img_id7468581626509198150.png/orig
Create:
Image #6357043
URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id6990201617655294894.jpeg/orig
Create:
Image #6357044
URL: https://avatars.mds.yandex.net/get-mpic/7650126/img_id787448148351002170.png/orig
Create:
Image #6357045
URL: https://avatars.mds.yandex.net/get-mpic/6303765/img_id7286524755491337149.png/orig
Create:
Image #6357046
URL: https://avatars.mds.yandex.net/get-mpic/7547374/img_id7867050461274718056.png/orig
Create:
Image #6357047
URL: https://avatars.mds.yandex.net/get-mpic/5094021/img_id4376050634817789793.png/orig
Donny Darko 09 July 2023 13:52:25
Create:
Description #3600747
Value: Type of heating boiler: gas, max. thermal power: 25.70 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, combustion chamber type: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3600748
Value: Gas
Create:
Number of circuits #3600749
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3600750
Value: Convection
Create:
Combustion chamber type #3600751
Value: Closed
Create:
Primary heat exchanger material #3600752
Value: Copper
Create:
Accommodation #3600753
Value: Wall
Create:
Power type #3600754
Value: Single-phase
Create:
Control #3600755
Value: Electronic
Create:
Equipment #3600756
Value: Built-in boiler
Create:
Functions #3600757
Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, power-on indication, flame modulation, underfloor heating connection
Create:
Minimum heat output #3600758
Value: 10.3 kW
Create:
Max. thermal power #3600759
Value: 25.7 kW
Create:
Maximum thermal load #3600760
Value: 25.7 kW
Create:
Efficiency #3600761
Value: 93 %
Create:
Heated area #3600762
Value: 260 m²
Create:
Maximum water pressure in the heating circuit #3600763
Value: 3 bar
Create:
Minimum heating medium temperature #3600764
Value: 35°C
Create:
Maximum coolant temperature #3600765
Value: 78°C
Create:
Expansion tank volume #3600766
Value: 10 l
Create:
Gas connection #3600767
Value: 3/4"
Create:
Heating circuit connection #3600768
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3600769
Value: 1/2"
Create:
Coaxial chimney diameter #3600770
Value: 60/100 mm
Create:
Burner #3600771
Value: Gas
Create:
Secondary heat exchanger material #3600772
Value: Stainless steel
Create:
The volume of the built-in boiler #3600773
Value: 60 l
Create:
Minimum temperature in the DHW circuit #3600774
Value: 35°C
Create:
Maximum temperature in the DHW circuit #3600775
Value: 60°C
Create:
Maximum water pressure in the DHW circuit #3600776
Value: 6 bar
Create:
Fuel #3600777
Value: Natural gas
Create:
Hot water capacity at t 30°C #3600778
Value: 15 l/min
Create:
Nominal natural gas pressure min. #3600779
Value: 17 mbar
Create:
Nominal pressure of natural gas #3600780
Value: 20 mbar
Create:
Permissible LPG pressure #3600781
Value: 28 mbar
Create:
Natural gas consumption #3600782
Value: 2.72 m³/hour
Create:
LPG consumption #3600783
Value: 2.02 kg/h
Create:
Depth #3600784
Value: 425 mm
Create:
Weight #3600785
Value: 65.2 kg
Create:
Image #6356952
URL: https://avatars.mds.yandex.net/get-mpic/5362248/img_id3154865026062554261.jpeg/orig
Create:
Image #6356953
URL: https://avatars.mds.yandex.net/get-mpic/5252557/img_id6058036538686693249.jpeg/orig
Create:
Preview image #6356954
URL: https://avatars.mds.yandex.net/get-mpic/5362248/img_id3154865026062554261.jpeg/orig
Donny Darko 30 April 2023 09:15:12
Name: Double-circuit with boiler Italtherm Time Max 24 F 25.7 kW; Catalog: Heating boilers