Change history for item: Italtherm City Basic 28 F 23.8 kW dual circuit

  1. Donny Darko 09 July 2023 13:50:38
    1. Create: Description #3600213
      Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3600214
      Value: Gas, convection
    3. Create: Burner #3600215
      Value: Gas
    4. Create: Number of circuits #3600216
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3600217
      Value: 9.40 - 23.80 kW
    6. Create: Thermal load #3600218
      Value: 10.90 - 29.80 kW
    7. Create: The combustion chamber #3600219
      Value: Closed
    8. Create: Efficiency #3600220
      Value: 93.1 %
    9. Create: Control #3600221
      Value: Electronic
    10. Create: Installation #3600222
      Value: Wall-mounted
    11. Create: Mains voltage #3600223
      Value: Single-phase
    12. Create: Peculiarities #3600224
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector, thermometer, water filter
    13. Create: Expansion tank volume #3600225
      Value: 8 l
    14. Create: Equipment #3600226
      Value: Display
    15. Create: Fuel #3600227
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3600228
      Value: 3.15 cu. m/hour
    17. Create: LPG consumption #3600229
      Value: 2.35 kg/hour
    18. Create: Nominal pressure of natural gas #3600230
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3600231
      Value: 40 mbar
    20. Create: Heat carrier temperature #3600232
      Value: 35 - 78 °С
    21. Create: Temperature in the DHW circuit #3600233
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3600234
      Value: 15.9 l/min
    23. Create: Hot water capacity at t 30°C #3600235
      Value: 13.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3600236
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3600237
      Value: 3 bar
    26. Create: Gas connection #3600238
      Value: 3/4"
    27. Create: Heating circuit connection #3600239
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3600240
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3600241
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3600242
      Value: 400x700x300mm
    31. Create: Weight #3600243
      Value: 34.5 kg
    32. Create: Image #6356706
      URL: https://avatars.mds.yandex.net/get-mpic/4466970/img_id6632494216729787569.jpeg/orig
    33. Create: Preview image #6356707
      URL: https://avatars.mds.yandex.net/get-mpic/4466970/img_id6632494216729787569.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:07
    Name: Italtherm City Basic 28 F 23.8 kW dual circuit; Catalog: Heating boilers