Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 13:50:38
Create:
Description #3600213
Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3600214
Value: Gas, convection
Create:
Burner #3600215
Value: Gas
Create:
Number of circuits #3600216
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3600217
Value: 9.40 - 23.80 kW
Create:
Thermal load #3600218
Value: 10.90 - 29.80 kW
Create:
The combustion chamber #3600219
Value: Closed
Create:
Efficiency #3600220
Value: 93.1 %
Create:
Control #3600221
Value: Electronic
Create:
Installation #3600222
Value: Wall-mounted
Create:
Mains voltage #3600223
Value: Single-phase
Create:
Peculiarities #3600224
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector, thermometer, water filter
Create:
Expansion tank volume #3600225
Value: 8 l
Create:
Equipment #3600226
Value: Display
Create:
Fuel #3600227
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3600228
Value: 3.15 cu. m/hour
Create:
LPG consumption #3600229
Value: 2.35 kg/hour
Create:
Nominal pressure of natural gas #3600230
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3600231
Value: 40 mbar
Create:
Heat carrier temperature #3600232
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3600233
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3600234
Value: 15.9 l/min
Create:
Hot water capacity at t 30°C #3600235
Value: 13.3 l/min
Create:
Max. water pressure in the DHW circuit #3600236
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3600237
Value: 3 bar
Create:
Gas connection #3600238
Value: 3/4"
Create:
Heating circuit connection #3600239
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3600240
Value: 1/2"
Create:
Coaxial chimney diameter #3600241
Value: 60/100 mm
Create:
Dimensions WxHxD #3600242
Value: 400x700x300mm
Create:
Weight #3600243
Value: 34.5 kg
Create:
Image #6356706
URL: https://avatars.mds.yandex.net/get-mpic/4466970/img_id6632494216729787569.jpeg/orig
Create:
Preview image #6356707
URL: https://avatars.mds.yandex.net/get-mpic/4466970/img_id6632494216729787569.jpeg/orig
Donny Darko 30 April 2023 09:15:07
Name: Italtherm City Basic 28 F 23.8 kW dual circuit; Catalog: Heating boilers