Change history for item: Italtherm City Basic 24 F 23.8 kW dual circuit

  1. Donny Darko 09 July 2023 13:50:34
    1. Create: Description #3600182
      Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3600183
      Value: Gas, convection
    3. Create: Burner #3600184
      Value: Gas
    4. Create: Number of circuits #3600185
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3600186
      Value: 8.50 - 23.80 kW
    6. Create: Thermal load #3600187
      Value: 9.90 - 25.70 kW
    7. Create: The combustion chamber #3600188
      Value: Closed
    8. Create: Efficiency #3600189
      Value: 92.8 %
    9. Create: Control #3600190
      Value: Electronic
    10. Create: Installation #3600191
      Value: Wall-mounted
    11. Create: Mains voltage #3600192
      Value: Single-phase
    12. Create: Peculiarities #3600193
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector, thermometer, water filter
    13. Create: Expansion tank volume #3600194
      Value: 8 l
    14. Create: Equipment #3600195
      Value: Display
    15. Create: Fuel #3600196
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3600197
      Value: 2.72 cu. m/hour
    17. Create: LPG consumption #3600198
      Value: 2.02 kg/hour
    18. Create: Nominal pressure of natural gas #3600199
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3600200
      Value: 40 mbar
    20. Create: Heat carrier temperature #3600201
      Value: 35 - 78 °С
    21. Create: Temperature in the DHW circuit #3600202
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3600203
      Value: 13.7 l/min
    23. Create: Hot water capacity at t 30°C #3600204
      Value: 11.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3600205
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3600206
      Value: 3 bar
    26. Create: Gas connection #3600207
      Value: 3/4"
    27. Create: Heating circuit connection #3600208
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3600209
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3600210
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3600211
      Value: 400x700x300mm
    31. Create: Weight #3600212
      Value: 34 kg
    32. Create: Image #6356704
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id3281956448606371036.jpeg/orig
    33. Create: Preview image #6356705
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id3281956448606371036.jpeg/orig