Change history for item: Italtherm City Basic 24 C 23.1 kW dual circuit

  1. Donny Darko 09 July 2023 13:50:27
    1. Create: Description #3600151
      Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3600152
      Value: Gas, convection
    3. Create: Burner #3600153
      Value: Gas
    4. Create: Number of circuits #3600154
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3600155
      Value: 8.60 - 23.10 kW
    6. Create: Thermal load #3600156
      Value: 9.90 - 25.70 kW
    7. Create: The combustion chamber #3600157
      Value: Open
    8. Create: Efficiency #3600158
      Value: 90 %
    9. Create: Control #3600159
      Value: Electronic
    10. Create: Installation #3600160
      Value: Wall-mounted
    11. Create: Mains voltage #3600161
      Value: Single-phase
    12. Create: Peculiarities #3600162
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector, thermometer, water filter
    13. Create: Expansion tank volume #3600163
      Value: 8 l
    14. Create: Equipment #3600164
      Value: Display
    15. Create: Fuel #3600165
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3600166
      Value: 2.72 cu. m/hour
    17. Create: LPG consumption #3600167
      Value: 2.02 kg/hour
    18. Create: Nominal pressure of natural gas #3600168
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3600169
      Value: 40 mbar
    20. Create: Heat carrier temperature #3600170
      Value: 35 - 78 °С
    21. Create: Temperature in the DHW circuit #3600171
      Value: 30 - 55 °С
    22. Create: Hot water capacity at t 25°C #3600172
      Value: 13.3 l/min
    23. Create: Hot water capacity at t 30°C #3600173
      Value: 11.1 l/min
    24. Create: Max. water pressure in the DHW circuit #3600174
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3600175
      Value: 3 bar
    26. Create: Gas connection #3600176
      Value: 3/4"
    27. Create: Heating circuit connection #3600177
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3600178
      Value: 1/2"
    29. Create: Chimney diameter #3600179
      Value: 130 mm
    30. Create: Dimensions WxHxD #3600180
      Value: 400x700x300mm
    31. Create: Weight #3600181
      Value: 29 kg
    32. Create: Image #6356702
      URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id7995575101429245713.jpeg/orig
    33. Create: Preview image #6356703
      URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id7995575101429245713.jpeg/orig
  2. Donny Darko 30 April 2023 09:15:07
    Name: Italtherm City Basic 24 C 23.1 kW dual circuit; Catalog: Heating boilers