Create:
Description #3600085
Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3600086
Value: Gas, convection
Create:
Burner #3600087
Value: Gas
Create:
Number of circuits #3600088
Value: Double-circuit
Create:
Thermal power #3600089
Value: 9.10 - 23.80 kW
Create:
Thermal load #3600090
Value: 10.30 - 25.70 kW
Create:
The combustion chamber #3600091
Value: Closed
Create:
Efficiency #3600092
Value: 92.8 %
Create:
Control #3600093
Value: Electronic
Create:
Installation #3600094
Value: Wall-mounted
Create:
Primary heat exchanger material #3600095
Value: Stainless steel
Create:
Mains voltage #3600096
Value: Single-phase
Create:
Peculiarities #3600097
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3600098
Value: 8 l
Create:
Equipment #3600099
Value: Display
Create:
Fuel #3600100
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3600101
Value: 2.72 cu. m/hour
Create:
LPG consumption #3600102
Value: 2.02 kg/hour
Create:
Nominal pressure of natural gas #3600103
Value: 20 mbar
Create:
Permissible LPG pressure #3600104
Value: 37 mbar
Create:
Heat carrier temperature #3600105
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3600106
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3600107
Value: 13.2 l/min
Create:
Hot water capacity at t 30°C #3600108
Value: 11 l/min
Create:
Max. water pressure in the DHW circuit #3600109
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3600110
Value: 3 bar
Create:
Gas connection #3600111
Value: 3/4"
Create:
Heating circuit connection #3600112
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3600113
Value: 1/2"
Create:
Coaxial chimney diameter #3600114
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3600115
Value: Yes
Create:
Dimensions WxHxD #3600116
Value: 400x700x300mm
Create:
Weight #3600117
Value: 3 kg
Create:
Image #6356698
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7832859213113431673/orig
Create:
Preview image #6356699
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7832859213113431673/orig
Donny Darko 30 April 2023 09:15:06
Name: Italtherm City Plus 24 F 23.8 kW dual circuit; Catalog: Heating boilers