      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3600050
      Value: Gas, convection
    3. Create: Burner #3600051
      Value: Gas
    4. Create: Number of circuits #3600052
      Value: Double-circuit
    5. Create: Thermal power #3600053
      Value: 8.80 - 23 kW
    6. Create: Thermal load #3600054
      Value: 10.30 - 25.70 kW
    7. Create: The combustion chamber #3600055
      Value: Open
    8. Create: Efficiency #3600056
      Value: 89.6 %
    9. Create: Control #3600057
      Value: Electronic
    10. Create: Installation #3600058
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3600059
      Value: Stainless steel
    12. Create: Mains voltage #3600060
      Value: Single-phase
    13. Create: Peculiarities #3600061
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3600062
      Value: 8 l
    15. Create: Equipment #3600063
      Value: Display
    16. Create: Fuel #3600064
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3600065
      Value: 2.72 cu. m/hour
    18. Create: LPG consumption #3600066
      Value: 2.02 kg/hour
    19. Create: Nominal pressure of natural gas #3600067
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3600068
      Value: 37 mbar
    21. Create: Heat carrier temperature #3600069
      Value: 35 - 78 °С
    22. Create: Temperature in the DHW circuit #3600070
      Value: 30 - 55 °С
    23. Create: Hot water capacity at t 25°C #3600071
      Value: 13.2 l/min
    24. Create: Hot water capacity at t 30°C #3600072
      Value: 11 l/min
    25. Create: Max. water pressure in the DHW circuit #3600073
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3600074
      Value: 3 bar
    27. Create: Gas connection #3600075
      Value: 3/4"
    28. Create: Heating circuit connection #3600076
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3600077
      Value: 1/2"
    30. Create: Chimney diameter #3600078
      Value: 130 mm
    31. Create: Dimensions WxHxD #3600079
      Value: 400x700x300mm
    32. Create: Weight #3600080
      Value: 29 kg
    33. Create: Image #6356696
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7832859213113431673/orig
    34. Create: Preview image #6356697
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7832859213113431673/orig
  2. Donny Darko 30 April 2023 09:15:06
    Name: Italtherm City Plus 24 C 23 kW double circuit; Catalog: Heating boilers