Change history for item: Gas boiler Victory AOGV 18T 18 kW double-circuit

  1. Donny Darko 09 July 2023 13:48:05
    1. Create: Description #3599692
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3599693
      Value: Gas, condensing
    3. Create: Burner #3599694
      Value: Gas
    4. Create: Number of circuits #3599695
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3599696
      Value: 7 - 18 kW
    6. Create: The combustion chamber #3599697
      Value: Closed
    7. Create: Efficiency #3599698
      Value: 92 %
    8. Create: Control #3599699
      Value: Electronic
    9. Create: Installation #3599700
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3599701
      Value: Copper
    11. Create: Mains voltage #3599702
      Value: Single-phase
    12. Create: Peculiarities #3599703
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3599704
      Value: 6 l
    14. Create: Equipment #3599705
      Value: Display
    15. Create: Fuel #3599706
      Value: Natural gas
    16. Create: Nominal pressure of natural gas #3599707
      Value: 13 - 20 mbar
    17. Create: Heat carrier temperature #3599708
      Value: 40 - 85 °С
    18. Create: Temperature in the DHW circuit #3599709
      Value: 30 - 60 °С
    19. Create: Hot water capacity at t 30°C #3599710
      Value: 11.4 l/min
    20. Create: Max. water pressure in the DHW circuit #3599711
      Value: 6 bar
    21. Create: Max. water pressure in the heating circuit #3599712
      Value: 3 bar
    22. Create: Gas connection #3599713
      Value: 3/4"
    23. Create: Heating circuit connection #3599714
      Value: 3/4"
    24. Create: Branch pipe for connecting the DHW circuit #3599715
      Value: 1/2"
    25. Create: Coaxial chimney diameter #3599716
      Value: 60/100 mm and 80/125 mm
    26. Create: Connection of a separate chimney diameter 80 mm #3599717
      Value: Yes
    27. Create: Dimensions WxHxD #3599718
      Value: 360x700x300 mm
    28. Create: Weight #3599719
      Value: 32 kg
    29. Create: Image #6356656
      URL: https://avatars.mds.yandex.net/get-mpic/1592982/img_id4520728168415967138/orig
    30. Create: Image #6356657
      URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id5916462018070077739/orig
    31. Create: Preview image #6356658
      URL: https://avatars.mds.yandex.net/get-mpic/1592982/img_id4520728168415967138/orig
  2. Donny Darko 30 April 2023 09:14:59
    Name: Gas boiler Victory AOGV 18T 18 kW double-circuit; Catalog: Heating boilers