Change history for item: Gas boiler Victory AOGV 29TM 29 kW double-circuit

  1. Donny Darko 09 July 2023 13:47:58
    1. Create: Description #3599632
      Value: Type of heating boiler: gas, max. thermal power: 29 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3599633
      Value: Gas, convection
    3. Create: Burner #3599634
      Value: Gas
    4. Create: Number of circuits #3599635
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3599636
      Value: 8 - 29 kW
    6. Create: Thermal load #3599637
      Value: 9.20 - 31.50 kW
    7. Create: The combustion chamber #3599638
      Value: Closed
    8. Create: Efficiency #3599639
      Value: 92 %
    9. Create: Control #3599640
      Value: Electronic
    10. Create: Installation #3599641
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3599642
      Value: Copper
    12. Create: Mains voltage #3599643
      Value: Single-phase
    13. Create: Peculiarities #3599644
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3599645
      Value: 6 l
    15. Create: Equipment #3599646
      Value: Display
    16. Create: Fuel #3599647
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3599648
      Value: 3.3 cu. m/hour
    18. Create: LPG consumption #3599649
      Value: 2.4 kg/hour
    19. Create: Nominal pressure of natural gas #3599650
      Value: 13 - 18 mbar
    20. Create: Permissible LPG pressure #3599651
      Value: 37 mbar
    21. Create: Heat carrier temperature #3599652
      Value: 40 - 85 °С
    22. Create: Temperature in the DHW circuit #3599653
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 30°C #3599654
      Value: 13.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3599655
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3599656
      Value: 3 bar
    26. Create: Gas connection #3599657
      Value: 3/4"
    27. Create: Heating circuit connection #3599658
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3599659
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3599660
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3599661
      Value: Yes
    31. Create: Dimensions WxHxD #3599662
      Value: 360x700x300 mm
    32. Create: Weight #3599663
      Value: 31 kg
    33. Create: Image #6356651
      URL: https://avatars.mds.yandex.net/get-mpic/3916156/img_id4957149206186013505.jpeg/orig
    34. Create: Preview image #6356652
      URL: https://avatars.mds.yandex.net/get-mpic/3916156/img_id4957149206186013505.jpeg/orig
  2. Donny Darko 30 April 2023 09:14:59
    Name: Gas boiler Victory AOGV 29TM 29 kW double-circuit; Catalog: Heating boilers