Change history for item: Gas boiler Victory AOGV 24TM 24 kW double-circuit

  1. Donny Darko 09 July 2023 13:47:54
    1. Create: Description #3599599
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3599600
      Value: Gas, convection
    3. Create: Burner #3599601
      Value: Gas
    4. Create: Number of circuits #3599602
      Value: Double-circuit
    5. Create: Thermal power #3599603
      Value: 7 - 24 kW
    6. Create: Thermal load #3599604
      Value: 7.90 - 25.70 kW
    7. Create: The combustion chamber #3599605
      Value: Closed
    8. Create: Efficiency #3599606
      Value: 93.1 %
    9. Create: Control #3599607
      Value: Electronic
    10. Create: Installation #3599608
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3599609
      Value: Copper
    12. Create: Secondary heat exchanger material #3599610
      Value: Stainless steel
    13. Create: Mains voltage #3599611
      Value: Single-phase
    14. Create: Peculiarities #3599612
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3599613
      Value: 6 l
    16. Create: Equipment #3599614
      Value: Display
    17. Create: Fuel #3599615
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3599616
      Value: 2.7 cu. m/hour
    19. Create: LPG consumption #3599617
      Value: 2 kg/hour
    20. Create: Nominal pressure of natural gas #3599618
      Value: 13 - 18 mbar
    21. Create: Permissible LPG pressure #3599619
      Value: 37 mbar
    22. Create: Heat carrier temperature #3599620
      Value: 40 - 85 °С
    23. Create: Temperature in the DHW circuit #3599621
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 30°C #3599622
      Value: 11.4 l/min
    25. Create: Max. water pressure in the DHW circuit #3599623
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3599624
      Value: 3 bar
    27. Create: Gas connection #3599625
      Value: 3/4"
    28. Create: Heating circuit connection #3599626
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3599627
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3599628
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3599629
      Value: Yes
    32. Create: Dimensions WxHxD #3599630
      Value: 360x700x300 mm
    33. Create: Weight #3599631
      Value: 31 kg
    34. Create: Image #6356649
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id4003067131051677016.jpeg/orig
    35. Create: Preview image #6356650
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id4003067131051677016.jpeg/orig
  2. Donny Darko 30 April 2023 09:14:58
    Name: Gas boiler Victory AOGV 24TM 24 kW double-circuit; Catalog: Heating boilers