Change history for item: Tiberis Cube 20F 20 kW

  1. Donny Darko 09 July 2023 12:56:44
    1. Create: Description #3590099
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3590100
      Value: Gas, convection
    3. Create: Burner #3590101
      Value: Gas
    4. Create: Number of circuits #3590102
      Value: Double-circuit
    5. Create: Thermal power #3590103
      Value: 8.20 - 20 kW
    6. Create: Thermal load #3590104
      Value: 9.10 - 22.10 kW
    7. Create: The combustion chamber #3590105
      Value: Closed
    8. Create: Efficiency #3590106
      Value: 90.5 %
    9. Create: Control #3590107
      Value: Electronic
    10. Create: Installation #3590108
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3590109
      Value: Copper
    12. Create: Mains voltage #3590110
      Value: Single-phase
    13. Create: Peculiarities #3590111
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3590112
      Value: 6 l
    15. Create: Equipment #3590113
      Value: Display
    16. Create: Fuel #3590114
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3590115
      Value: 2.27 cu. m/hour
    18. Create: LPG consumption #3590116
      Value: 1.89 kg/hour
    19. Create: Nominal pressure of natural gas #3590117
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3590118
      Value: 28 mbar
    21. Create: Heat carrier temperature #3590119
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3590120
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3590121
      Value: 11.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3590122
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3590123
      Value: 3 bar
    26. Create: Gas connection #3590124
      Value: 3/4"
    27. Create: Heating circuit connection #3590125
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3590126
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3590127
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3590128
      Value: Yes
    31. Create: Dimensions WxHxD #3590129
      Value: 400x700x300mm
    32. Create: Weight #3590130
      Value: 35 kg
    33. Create: Image #6355241
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id3999246731661307967.jpeg/orig
    34. Create: Preview image #6355242
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id3999246731661307967.jpeg/orig
  2. Donny Darko 30 April 2023 09:12:18
    Name: Tiberis Cube 20F 20 kW; Catalog: Heating boilers