Change history for item: Tiberis Cube 16F 16 kW

  1. Donny Darko 09 July 2023 12:56:35
    1. Create: Description #3590035
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3590036
      Value: Gas, convection
    3. Create: Burner #3590037
      Value: Gas
    4. Create: Number of circuits #3590038
      Value: Double-circuit
    5. Create: Thermal power #3590039
      Value: 8.20 - 16 kW
    6. Create: Thermal load #3590040
      Value: 9.60 - 18.30 kW
    7. Create: The combustion chamber #3590041
      Value: Closed
    8. Create: Efficiency #3590042
      Value: 90.5 %
    9. Create: Control #3590043
      Value: Electronic
    10. Create: Installation #3590044
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3590045
      Value: Copper
    12. Create: Mains voltage #3590046
      Value: Single-phase
    13. Create: Peculiarities #3590047
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3590048
      Value: 6 l
    15. Create: Equipment #3590049
      Value: Display
    16. Create: Fuel #3590050
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3590051
      Value: 1.8 cu. m/hour
    18. Create: LPG consumption #3590052
      Value: 1.4 kg/hour
    19. Create: Nominal pressure of natural gas #3590053
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3590054
      Value: 28 mbar
    21. Create: Heat carrier temperature #3590055
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3590056
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3590057
      Value: 9.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3590058
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3590059
      Value: 3 bar
    26. Create: Gas connection #3590060
      Value: 3/4"
    27. Create: Heating circuit connection #3590061
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3590062
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3590063
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3590064
      Value: Yes
    31. Create: Dimensions WxHxD #3590065
      Value: 400x700x300mm
    32. Create: Weight #3590066
      Value: 35 kg
    33. Create: Image #6355237
      URL: https://avatars.mds.yandex.net/get-mpic/4721581/img_id2023190939356191390.jpeg/orig
    34. Create: Preview image #6355238
      URL: https://avatars.mds.yandex.net/get-mpic/4721581/img_id2023190939356191390.jpeg/orig
  2. Donny Darko 30 April 2023 09:12:17
    Name: Tiberis Cube 16F 16 kW; Catalog: Heating boilers