Change history for item: Tiberis Cube 13F 13 kW

  1. Donny Darko 09 July 2023 12:56:16
    1. Create: Description #3590003
      Value: Type of heating boiler: gas, max. thermal power: 13 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3590004
      Value: Gas, convection
    3. Create: Burner #3590005
      Value: Gas
    4. Create: Number of circuits #3590006
      Value: Double-circuit
    5. Create: Thermal power #3590007
      Value: 8.20 - 13 kW
    6. Create: Thermal load #3590008
      Value: 9.10 - 14.50 kW
    7. Create: The combustion chamber #3590009
      Value: Closed
    8. Create: Efficiency #3590010
      Value: 90.5 %
    9. Create: Control #3590011
      Value: Electronic
    10. Create: Installation #3590012
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3590013
      Value: Copper
    12. Create: Mains voltage #3590014
      Value: Single-phase
    13. Create: Peculiarities #3590015
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3590016
      Value: 6 l
    15. Create: Equipment #3590017
      Value: Display
    16. Create: Fuel #3590018
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3590019
      Value: 1.46 cu. m/hour
    18. Create: LPG consumption #3590020
      Value: 1.17 kg/hour
    19. Create: Nominal pressure of natural gas #3590021
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3590022
      Value: 28 mbar
    21. Create: Heat carrier temperature #3590023
      Value: 30 - 80 °С
    22. Create: Temperature in the DHW circuit #3590024
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3590025
      Value: 7.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3590026
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3590027
      Value: 3 bar
    26. Create: Gas connection #3590028
      Value: 3/4"
    27. Create: Heating circuit connection #3590029
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3590030
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3590031
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3590032
      Value: Yes
    31. Create: Dimensions WxHxD #3590033
      Value: 400x700x300mm
    32. Create: Weight #3590034
      Value: 35 kg
    33. Create: Image #6355235
      URL: https://avatars.mds.yandex.net/get-mpic/4449143/img_id4379656034329426695.jpeg/orig
    34. Create: Preview image #6355236
      URL: https://avatars.mds.yandex.net/get-mpic/4449143/img_id4379656034329426695.jpeg/orig
  2. Donny Darko 30 April 2023 09:12:17
    Name: Tiberis Cube 13F 13 kW; Catalog: Heating boilers