Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 12:56:03
Create:
Description #3589908
Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3589909
Value: Gas, convection
Create:
Burner #3589910
Value: Gas
Create:
Number of circuits #3589911
Value: Double-circuit
Create:
Thermal power #3589912
Value: 9.10 - 23.80 kW
Create:
Thermal load #3589913
Value: 10.30 - 25.70 kW
Create:
The combustion chamber #3589914
Value: Closed
Create:
Efficiency #3589915
Value: 92.8 %
Create:
Control #3589916
Value: Electronic
Create:
Installation #3589917
Value: Wall-mounted
Create:
Secondary heat exchanger material #3589918
Value: Stainless steel
Create:
Mains voltage #3589919
Value: Single-phase
Create:
Peculiarities #3589920
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3589921
Value: 60 l
Create:
Expansion tank volume #3589922
Value: 10 l
Create:
Equipment #3589923
Value: Built-in boiler, display
Create:
Fuel #3589924
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3589925
Value: 2.72 cu. m/hour
Create:
LPG consumption #3589926
Value: 2.02 kg/hour
Create:
Nominal pressure of natural gas #3589927
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3589928
Value: 40 mbar
Create:
Heat carrier temperature #3589929
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3589930
Value: 30 - 60 °С
Create:
Hot water capacity at t 30°C #3589931
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3589932
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3589933
Value: 3 bar
Create:
Gas connection #3589934
Value: 3/4"
Create:
Heating circuit connection #3589935
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3589936
Value: 1/2"
Create:
Coaxial chimney diameter #3589937
Value: 60/100 mm
Create:
Dimensions WxHxD #3589938
Value: 900x600x425mm
Create:
Weight #3589939
Value: 60 kg
Create:
Image #6355225
URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id6293385723722015865.jpeg/orig
Create:
Image #6355226
URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id7890599464763723277.jpeg/orig
Create:
Image #6355227
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id4647963561622421055.jpeg/orig
Create:
Preview image #6355228
URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id6293385723722015865.jpeg/orig
Donny Darko 30 April 2023 09:12:16
Name: Tiberis Triton 24F 23.8 kW; Catalog: Heating boilers