Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 12:55:54
Create:
Description #3589844
Value: Type of heating boiler: gas, max. heating power: 27.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3589845
Value: Gas, convection
Create:
Burner #3589846
Value: Gas
Create:
Number of circuits #3589847
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3589848
Value: 9.40 - 27.70 kW
Create:
Thermal load #3589849
Value: 10.90 - 29.80 kW
Create:
The combustion chamber #3589850
Value: Closed
Create:
Efficiency #3589851
Value: 93.1 %
Create:
Control #3589852
Value: Electronic
Create:
Installation #3589853
Value: Wall-mounted
Create:
Primary heat exchanger material #3589854
Value: Copper
Create:
Mains voltage #3589855
Value: Single-phase
Create:
Peculiarities #3589856
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3589857
Value: 8 l
Create:
Equipment #3589858
Value: Display
Create:
Fuel #3589859
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3589860
Value: 3.15 cu. m/hour
Create:
LPG consumption #3589861
Value: 2.35 kg/hour
Create:
Nominal pressure of natural gas #3589862
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3589863
Value: 40 mbar
Create:
Heat carrier temperature #3589864
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3589865
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3589866
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3589867
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3589868
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3589869
Value: 3 bar
Create:
Gas connection #3589870
Value: 3/4"
Create:
Heating circuit connection #3589871
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3589872
Value: 1/2"
Create:
Coaxial chimney diameter #3589873
Value: 60/100 mm
Create:
Dimensions WxHxD #3589874
Value: 400x700x300mm
Create:
Weight #3589875
Value: 34.5 kg
Create:
Image #6355221
URL: https://avatars.mds.yandex.net/get-mpic/4372348/img_id7437702037224596874.jpeg/orig
Create:
Preview image #6355222
URL: https://avatars.mds.yandex.net/get-mpic/4372348/img_id7437702037224596874.jpeg/orig
Donny Darko 30 April 2023 09:12:16
Name: Tiberis Oberon 28F 27.7 kW; Catalog: Heating boilers