    1. Create: Description #3589812
      Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3589813
      Value: Gas, convection
    3. Create: Burner #3589814
      Value: Gas
    4. Create: Number of circuits #3589815
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3589816
      Value: 8.60 - 23.10 kW
    6. Create: Thermal load #3589817
      Value: 10.30 - 25.70 kW
    7. Create: The combustion chamber #3589818
      Value: Open
    8. Create: Efficiency #3589819
      Value: 90 %
    9. Create: Control #3589820
      Value: Electronic
    10. Create: Installation #3589821
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3589822
      Value: Copper
    12. Create: Mains voltage #3589823
      Value: Single-phase
    13. Create: Peculiarities #3589824
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3589825
      Value: 8 l
    15. Create: Equipment #3589826
      Value: Display
    16. Create: Fuel #3589827
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3589828
      Value: 2.72 cu. m/hour
    18. Create: LPG consumption #3589829
      Value: 2.02 kg/hour
    19. Create: Nominal pressure of natural gas #3589830
      Value: 17 - 25 mbar
    20. Create: Permissible LPG pressure #3589831
      Value: 40 mbar
    21. Create: Heat carrier temperature #3589832
      Value: 35 - 78 °С
    22. Create: Temperature in the DHW circuit #3589833
      Value: 30 - 55 °С
    23. Create: Hot water capacity at t 25°C #3589834
      Value: 13.3 l/min
    24. Create: Hot water capacity at t 30°C #3589835
      Value: 11.1 l/min
    25. Create: Max. water pressure in the DHW circuit #3589836
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3589837
      Value: 3 bar
    27. Create: Gas connection #3589838
      Value: 3/4"
    28. Create: Heating circuit connection #3589839
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3589840
      Value: 1/2"
    30. Create: Chimney diameter #3589841
      Value: 130 mm
    31. Create: Dimensions WxHxD #3589842
      Value: 400x700x300mm
    32. Create: Weight #3589843
      Value: 29 kg
    33. Create: Image #6355219
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id2557340775707916004.jpeg/orig
    34. Create: Preview image #6355220
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id2557340775707916004.jpeg/orig
  2. Donny Darko 30 April 2023 09:12:15
    Name: Tiberis Oberon 24C 23.1 kW; Catalog: Heating boilers