Description #3589780
Value: Type of heating boiler: gas, max. heating power: 18.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3589781
Value: Gas, convection
Create:
Burner #3589782
Value: Gas
Create:
Number of circuits #3589783
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3589784
Value: 7.90 - 18.60 kW
Create:
Thermal load #3589785
Value: 9.20 - 18.30 kW
Create:
The combustion chamber #3589786
Value: Closed
Create:
Efficiency #3589787
Value: 91.5 %
Create:
Control #3589788
Value: Electronic
Create:
Installation #3589789
Value: Wall-mounted
Create:
Primary heat exchanger material #3589790
Value: Copper
Create:
Mains voltage #3589791
Value: Single-phase
Create:
Peculiarities #3589792
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3589793
Value: 8 l
Create:
Equipment #3589794
Value: Outdoor temperature sensor, display
Create:
Fuel #3589795
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3589796
Value: 2.15 cu. m/hour
Create:
LPG consumption #3589797
Value: 1.6 kg/hour
Create:
Nominal pressure of natural gas #3589798
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3589799
Value: 40 mbar
Create:
Heat carrier temperature #3589800
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3589801
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3589802
Value: 10.6 l/min
Create:
Hot water capacity at t 30°C #3589803
Value: 8.9 l/min
Create:
Max. water pressure in the DHW circuit #3589804
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3589805
Value: 3 bar
Create:
Gas connection #3589806
Value: 3/4"
Create:
Heating circuit connection #3589807
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3589808
Value: 1/2"
Create:
Coaxial chimney diameter #3589809
Value: 60/100 mm
Create:
Dimensions WxHxD #3589810
Value: 400x700x300mm
Create:
Weight #3589811
Value: 33.5 kg