Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 12:55:40
Create:
Description #3589748
Value: Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3589749
Value: Gas, convection
Create:
Burner #3589750
Value: Gas
Create:
Number of circuits #3589751
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3589752
Value: 8.50 - 23.80 kW
Create:
Thermal load #3589753
Value: 9.90 - 25.70 kW
Create:
The combustion chamber #3589754
Value: Closed
Create:
Efficiency #3589755
Value: 92.8 %
Create:
Control #3589756
Value: Electronic
Create:
Installation #3589757
Value: Wall-mounted
Create:
Primary heat exchanger material #3589758
Value: Copper
Create:
Mains voltage #3589759
Value: Single-phase
Create:
Peculiarities #3589760
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3589761
Value: 8 l
Create:
Equipment #3589762
Value: Display
Create:
Fuel #3589763
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3589764
Value: 2.72 cu. m/hour
Create:
LPG consumption #3589765
Value: 2.02 kg/hour
Create:
Nominal pressure of natural gas #3589766
Value: 17 - 25 mbar
Create:
Permissible LPG pressure #3589767
Value: 40 mbar
Create:
Heat carrier temperature #3589768
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3589769
Value: 30 - 55 °С
Create:
Hot water capacity at t 25°C #3589770
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3589771
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3589772
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3589773
Value: 3 bar
Create:
Gas connection #3589774
Value: 3/4"
Create:
Heating circuit connection #3589775
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3589776
Value: 1/2"
Create:
Coaxial chimney diameter #3589777
Value: 60/100 mm
Create:
Dimensions WxHxD #3589778
Value: 400x700x300mm
Create:
Weight #3589779
Value: 34 kg
Create:
Image #6355215
URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id5249979501145131745.jpeg/orig
Create:
Preview image #6355216
URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id5249979501145131745.jpeg/orig
Donny Darko 30 April 2023 09:12:15
Name: Tiberis Oberon 24F 23.8 kW; Catalog: Heating boilers