Change history for item: GRAND ITAL ESATTO 24-S 23.7 kW dual circuit

  1. Donny Darko 09 July 2023 12:05:22
    1. Create: Description #3582802
      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, control: electronic
    2. Create: Type of heating boiler #3582803
      Value: Gas, convection
    3. Create: Burner #3582804
      Value: Gas
    4. Create: Number of circuits #3582805
      Value: Double-circuit
    5. Create: Thermal power #3582806
      Value: 11.10 - 23.70 kW
    6. Create: Thermal load #3582807
      Value: 12.50 - 25.50 kW
    7. Create: The combustion chamber #3582808
      Value: Closed
    8. Create: Efficiency #3582809
      Value: 93 %
    9. Create: Control #3582810
      Value: Electronic
    10. Create: Installation #3582811
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3582812
      Value: Copper
    12. Create: Secondary heat exchanger material #3582813
      Value: Stainless steel
    13. Create: Peculiarities #3582814
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3582815
      Value: 7 l
    15. Create: Equipment #3582816
      Value: Display
    16. Create: Fuel #3582817
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3582818
      Value: 2.7 cu. m/hour
    18. Create: LPG consumption #3582819
      Value: 2.01 kg/h
    19. Create: Nominal pressure of natural gas #3582820
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3582821
      Value: 37 mbar
    21. Create: Heat carrier temperature #3582822
      Value: 35 - 78 °С
    22. Create: Temperature in the DHW circuit #3582823
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3582824
      Value: 13.9 l/min
    24. Create: Hot water capacity at t 30°C #3582825
      Value: 11.6 l/min
    25. Create: Hot water capacity at t 35°C #3582826
      Value: 9.9 l/min
    26. Create: Hot water capacity at t 40°C #3582827
      Value: 8.7 l/min
    27. Create: Hot water capacity at t 45°C #3582828
      Value: 7.7 l/min
    28. Create: Max. water pressure in the DHW circuit #3582829
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3582830
      Value: 3 bar
    30. Create: Gas connection #3582831
      Value: 1/2"
    31. Create: Heating circuit connection #3582832
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3582833
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3582834
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3582835
      Value: Yes
    35. Create: Dimensions WxHxD #3582836
      Value: 420x750x315 mm
    36. Create: Weight #3582837
      Value: 28 kg
    37. Create: Image #6354339
      URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id2630267657556554787.jpeg/orig
    38. Create: Preview image #6354340
      URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id2630267657556554787.jpeg/orig
  2. Donny Darko 30 April 2023 09:10:16
    Name: GRAND ITAL ESATTO 24-S 23.7 kW dual circuit; Catalog: Heating boilers