Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 12:05:09
Create:
Description #3582729
Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3582730
Value: Gas, convection
Create:
Burner #3582731
Value: Gas
Create:
Number of circuits #3582732
Value: Double-circuit
Create:
Thermal power #3582733
Value: 11.10 - 23.70 kW
Create:
Thermal load #3582734
Value: 12.50 - 25.50 kW
Create:
The combustion chamber #3582735
Value: Closed
Create:
Efficiency #3582736
Value: 93 %
Create:
Control #3582737
Value: Electronic
Create:
Installation #3582738
Value: Wall-mounted
Create:
Primary heat exchanger material #3582739
Value: Copper
Create:
Secondary heat exchanger material #3582740
Value: Stainless steel
Create:
Mains voltage #3582741
Value: Single-phase
Create:
Peculiarities #3582742
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3582743
Value: 7 l
Create:
Equipment #3582744
Value: Outdoor temperature sensor, display
Create:
Fuel #3582745
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3582746
Value: 2.7 cu. m/hour
Create:
LPG consumption #3582747
Value: 2.01 kg/h
Create:
Nominal pressure of natural gas #3582748
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3582749
Value: 37 mbar
Create:
Heat carrier temperature #3582750
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3582751
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3582752
Value: 13.3 l/min
Create:
Hot water capacity at t 30°C #3582753
Value: 11.1 l/min
Create:
Hot water capacity at t 35°C #3582754
Value: 9.5 l/min
Create:
Hot water capacity at t 40°C #3582755
Value: 8.3 l/min
Create:
Hot water capacity at t 45°C #3582756
Value: 7.4 l/min
Create:
Max. water pressure in the DHW circuit #3582757
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3582758
Value: 3 bar
Create:
Gas connection #3582759
Value: 1/2"
Create:
Heating circuit connection #3582760
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3582761
Value: 1/2"
Create:
Coaxial chimney diameter #3582762
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3582763
Value: Yes
Create:
Dimensions WxHxD #3582764
Value: 400x700x250mm
Create:
Weight #3582765
Value: 25 kg
Create:
Image #6354335
URL: https://avatars.mds.yandex.net/get-mpic/4080763/img_id2462697817101584228.jpeg/orig
Create:
Preview image #6354336
URL: https://avatars.mds.yandex.net/get-mpic/4080763/img_id2462697817101584228.jpeg/orig
Donny Darko 30 April 2023 09:10:15
Name: GRAND ITAL ALBA 24- S 23.7 kW double-circuit; Catalog: Heating boilers