Change history for item: - Platinum 3.25 29.1 kW

  1. Donny Darko 09 July 2023 11:43:34
    1. Create: Description #3578788
      Value: Type of heating boiler: gas, max. heating power: 29.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3578789
      Value: Gas, convection
    3. Create: Burner #3578790
      Value: Gas
    4. Create: Number of circuits #3578791
      Value: Double-circuit
    5. Create: Thermal power #3578792
      Value: 12.20 - 29.10 kW
    6. Create: The combustion chamber #3578793
      Value: Closed
    7. Create: Efficiency #3578794
      Value: 92.6 %
    8. Create: Control #3578795
      Value: Electronic
    9. Create: Installation #3578796
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3578797
      Value: Copper
    11. Create: Secondary heat exchanger material #3578798
      Value: Stainless steel
    12. Create: Mains voltage #3578799
      Value: Single-phase
    13. Create: Peculiarities #3578800
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3578801
      Value: 5.3 l
    15. Create: Equipment #3578802
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3578803
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3578804
      Value: 3.41 cu. m/hour
    18. Create: LPG consumption #3578805
      Value: 1.4 kg/hour
    19. Create: Nominal pressure of natural gas #3578806
      Value: 10.70 - 24.50 mbar
    20. Create: Permissible LPG pressure #3578807
      Value: 35 mbar
    21. Create: Heat carrier temperature #3578808
      Value: 25 - 80 °C
    22. Create: Temperature in the DHW circuit #3578809
      Value: 40 - 60 °С
    23. Create: Hot water capacity at t 25°C #3578810
      Value: 16.7 l/min
    24. Create: Hot water capacity at t 40°C #3578811
      Value: 10.4 l/min
    25. Create: Max. water pressure in the DHW circuit #3578812
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3578813
      Value: 3 bar
    27. Create: Gas connection #3578814
      Value: 3/4"
    28. Create: Heating circuit connection #3578815
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3578816
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3578817
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3578818
      Value: Yes
    32. Create: Dimensions WxHxD #3578819
      Value: 460x700x217 mm
    33. Create: Weight #3578820
      Value: 26 kg