Change history for item: - Platinum 3.20 23.3 kW

  1. Donny Darko 09 July 2023 11:43:29
    1. Create: Description #3578755
      Value: Type of heating boiler: gas, max. heating power: 23.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3578756
      Value: Gas, convection
    3. Create: Burner #3578757
      Value: Gas
    4. Create: Number of circuits #3578758
      Value: Double-circuit
    5. Create: Thermal power #3578759
      Value: 8.60 - 23.30 kW
    6. Create: The combustion chamber #3578760
      Value: Closed
    7. Create: Efficiency #3578761
      Value: 92.6 %
    8. Create: Control #3578762
      Value: Electronic
    9. Create: Installation #3578763
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3578764
      Value: Copper
    11. Create: Secondary heat exchanger material #3578765
      Value: Stainless steel
    12. Create: Mains voltage #3578766
      Value: Single-phase
    13. Create: Peculiarities #3578767
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3578768
      Value: 5.3 l
    15. Create: Equipment #3578769
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3578770
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3578771
      Value: 2.73 cu. m/hour
    18. Create: LPG consumption #3578772
      Value: 0.9 kg/hour
    19. Create: Nominal pressure of natural gas #3578773
      Value: 10.70 - 24.50 mbar
    20. Create: Permissible LPG pressure #3578774
      Value: 35 mbar
    21. Create: Heat carrier temperature #3578775
      Value: 25 - 80 °C
    22. Create: Temperature in the DHW circuit #3578776
      Value: 40 - 60 °С
    23. Create: Hot water capacity at t 25°C #3578777
      Value: 13.3 l/min
    24. Create: Hot water capacity at t 40°C #3578778
      Value: 8.3 l/min
    25. Create: Max. water pressure in the DHW circuit #3578779
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3578780
      Value: 3 bar
    27. Create: Gas connection #3578781
      Value: 1/2"
    28. Create: Heating circuit connection #3578782
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3578783
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3578784
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3578785
      Value: Yes
    32. Create: Dimensions WxHxD #3578786
      Value: 438x684x210 mm
    33. Create: Weight #3578787
      Value: 24 kg
    34. Create: Image #6353843
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7657317705348103309.jpeg/orig
    35. Create: Preview image #6353844
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7657317705348103309.jpeg/orig
  2. Donny Darko 30 April 2023 09:09:17
    Name: - Platinum 3.20 23.3 kW; Catalog: Heating boilers