Change history for item: - Platinum C 3.50 58.1 kW

  1. Donny Darko 09 July 2023 11:43:02
    1. Create: Description #3578659
      Value: Type of heating boiler: gas, max. thermal power: 58.10 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, combustion chamber type: closed, power type: single-phase, control: electric
    2. Create: Type of heating boiler #3578660
      Value: Gas, condensing
    3. Create: Burner #3578661
      Value: Gas
    4. Create: Number of circuits #3578662
      Value: Double-circuit
    5. Create: Thermal power #3578663
      Value: 17.40 - 58.10 kW
    6. Create: The combustion chamber #3578664
      Value: Closed
    7. Create: Efficiency #3578665
      Value: 108.4 %
    8. Create: Control #3578666
      Value: Electronic
    9. Create: Installation #3578667
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3578668
      Value: Copper
    11. Create: Secondary heat exchanger material #3578669
      Value: Stainless steel
    12. Create: Mains voltage #3578670
      Value: Single-phase
    13. Create: Peculiarities #3578671
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3578672
      Value: 9 l
    15. Create: Equipment #3578673
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3578674
      Value: Natural gas
    17. Create: Natural gas consumption #3578675
      Value: 3.8 cu. m/hour
    18. Create: Heat carrier temperature #3578676
      Value: 25 - 80 °C
    19. Create: Temperature in the DHW circuit #3578677
      Value: 37 - 60 °С
    20. Create: Hot water capacity at t 25°C #3578678
      Value: 3.33 l/min
    21. Create: Hot water capacity at t 40°C #3578679
      Value: 20.8 l/min
    22. Create: Max. water pressure in the DHW circuit #3578680
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3578681
      Value: 3 bar
    24. Create: Gas connection #3578682
      Value: 3/4"
    25. Create: Heating circuit connection #3578683
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3578684
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3578685
      Value: 75/100 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3578686
      Value: Yes
    29. Create: Dimensions WxHxD #3578687
      Value: 471x729x344 mm
    30. Create: Weight #3578688
      Value: 44 kg
    31. Create: Image #6353837
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id3788956544677811207.jpeg/orig
    32. Create: Preview image #6353838
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id3788956544677811207.jpeg/orig
  2. Donny Darko 30 April 2023 09:09:16
    Name: - Platinum C 3.50 58.1 kW; Catalog: Heating boilers