Change history for item: - Platinum C 3.35 40.7 kW

  1. Donny Darko 09 July 2023 11:42:41
    1. Create: Description #3578629
      Value: Type of heating boiler: gas, max. thermal power: 40.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3578630
      Value: Gas, condensing
    3. Create: Burner #3578631
      Value: Gas
    4. Create: Number of circuits #3578632
      Value: Double-circuit
    5. Create: Thermal power #3578633
      Value: 12.80 - 40.70 kW
    6. Create: The combustion chamber #3578634
      Value: Closed
    7. Create: Efficiency #3578635
      Value: 107.9 %
    8. Create: Control #3578636
      Value: Electronic
    9. Create: Installation #3578637
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3578638
      Value: Copper
    11. Create: Secondary heat exchanger material #3578639
      Value: Stainless steel
    12. Create: Mains voltage #3578640
      Value: Single-phase
    13. Create: Peculiarities #3578641
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3578642
      Value: 5.3 l
    15. Create: Equipment #3578643
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3578644
      Value: Natural gas
    17. Create: Natural gas consumption #3578645
      Value: 3.8 cu. m/hour
    18. Create: Heat carrier temperature #3578646
      Value: 25 - 80 °C
    19. Create: Temperature in the DHW circuit #3578647
      Value: 37 - 60 °С
    20. Create: Hot water capacity at t 25°C #3578648
      Value: 2.33 l/min
    21. Create: Hot water capacity at t 40°C #3578649
      Value: 14.6 l/min
    22. Create: Max. water pressure in the DHW circuit #3578650
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3578651
      Value: 3 bar
    24. Create: Gas connection #3578652
      Value: 3/4"
    25. Create: Heating circuit connection #3578653
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3578654
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3578655
      Value: 60/100 mm and 80/125 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3578656
      Value: Yes
    29. Create: Dimensions WxHxD #3578657
      Value: 460x700x205mm
    30. Create: Weight #3578658
      Value: 31 kg
    31. Create: Image #6353835
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id2287403591486159575.jpeg/orig
    32. Create: Preview image #6353836
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id2287403591486159575.jpeg/orig
  2. Donny Darko 30 April 2023 09:09:15
    Name: - Platinum C 3.35 40.7 kW; Catalog: Heating boilers