Change history for item: Combined Atem -9 KS-GV-016SN / AOTV-12 16 kW double-circuit

  1. Donny Darko 09 July 2023 09:58:14
    1. Create: Description #3560639
      Value: Type of heating boiler: combined, max. thermal power: 16 kW, number of circuits: double-circuit, placement: floor, fuel: firewood, natural gas, coal, type of combustion chamber: open, control: mechanical
    2. Create: Type of heating boiler #3560640
      Value: Combined
    3. Create: The principle of operation on solid fuel #3560641
      Value: Classical
    4. Create: Burner #3560642
      Value: Gas
    5. Create: Number of circuits #3560643
      Value: Double-circuit
    6. Create: Max. thermal power #3560644
      Value: 16 kW
    7. Create: Non-volatile #3560645
      Value: Yes
    8. Create: The combustion chamber #3560646
      Value: Open
    9. Create: Heated area #3560647
      Value: 160 sq.m
    10. Create: Efficiency #3560648
      Value: 92 %
    11. Create: Control #3560649
      Value: Mechanical
    12. Create: Installation #3560650
      Value: Floor
    13. Create: Primary heat exchanger material #3560651
      Value: Steel
    14. Create: Secondary heat exchanger material #3560652
      Value: Steel
    15. Create: Peculiarities #3560653
      Value: Thermometer
    16. Create: Fuel #3560654
      Value: Wood, natural gas, coal
    17. Create: Natural gas consumption #3560655
      Value: 1.58 cu. m/hour
    18. Create: Nominal pressure of natural gas #3560656
      Value: 6.35 - 17.64 mbar
    19. Create: Heat carrier temperature #3560657
      Value: 60 - 90 °С
    20. Create: Hot water capacity at t 35°C #3560658
      Value: 5.33 l/min
    21. Create: Max. water pressure in the DHW circuit #3560659
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3560660
      Value: 1.5 bar
    23. Create: Gas connection #3560661
      Value: 1/2"
    24. Create: Heating circuit connection #3560662
      Value: 2"
    25. Create: Branch pipe for connecting the DHW circuit #3560663
      Value: 1/2"
    26. Create: Chimney diameter #3560664
      Value: 128 mm
    27. Create: Dimensions WxHxD #3560665
      Value: 595x1135x580 mm
    28. Create: Weight #3560666
      Value: 134 kg
    29. Create: Additional Information #3560667
      Value: Characteristics when working on solid fuel: max. thermal power - 12 kW, heated area - 120 sq. m., efficiency - 78%
    30. Create: Image #6351215
      URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id1575644157013954833.jpeg/orig
    31. Create: Preview image #6351216
      URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id1575644157013954833.jpeg/orig
  2. Donny Darko 30 April 2023 09:04:13
    Name: Combined Atem -9 KS-GV-016SN / AOTV-12 16 kW double-circuit; Catalog: Heating boilers